Drive bay
Supported drive type
Eight 2.5-inch drive bays
Hot-swap SAS/SATA/NVMe HDD or SSD (NVMe drives are
supported only in bays 4–7 if an AnyBay backplane is installed)
Sixteen 2.5-inch drive bays
Hot-swap SAS/SATA/NVMe HDD or SSD (NVMe drives are
supported only in bays 4–7 if an AnyBay backplane is installed)
Twenty 2.5-inch drive bays
Hot-swap SAS/SATA/NVMe HDD or SSD (NVMe drives are
supported only in bays 4–7 if an AnyBay backplane is installed)
Four 3.5-inch drive bays
– Simple-swap SATA HDD
– Hot-swap SAS/SATA HDD or SSD
Eight 3.5-inch drive bays
– Simple-swap SATA HDD
– Hot-swap SAS/SATA HDD or SSD
Eight 3.5-inch drive bays and four 2.5-inch drive
bays
Hot-swap SAS/SATA HDD or SSD
To locate the storage drives or drive bays, see “Front view” on page 15.
• Optical drive
Some server models have two optical drive bays. For more information, see “Front view” on page 15.
• Tape drive
A tape drive enables you to store data on tape media. For server models with two optical drive bays, you
can install an internal tape drive in the optical-drive bay 2.
• M.2 drive
Your server supports one M.2 backplane which provides an easy way for data storage. You can install up
to two M.2 drives into the M.2 backplane. For more information, see “Install the M.2 backplane and M.2
drive” on page 84.
Expansion slots
The server has six expansion slots on the system board for installing appropriate Peripheral Component
Interconnect Express (PCIe) adapters.
• For processor 1
– PCIe slot 1: PCIe x8 (x8, x4, x1), full-height, half-length
– PCIe slot 2: PCIe x16 (x16, x8, x4, x1), full-height, half-length
– PCIe slot 3: PCIe x16 (x16, x8, x4, x1), full-height, full-length, double-width
– PCIe slot 6: PCIe x8 (x4, x1), full-height, full-length
• For processor 2
– PCIe slot 4: PCIe x16 (x8, x4, x1), full-height, full-length
– PCIe slot 5: PCIe x16 (x16, x8, x4, x1), full-height, full-length, double-width
The following RAID adapters can be installed in an appropriate PCIe slot.
• A RAID 530-8i SAS/SATA adapter that supports JBOD mode and RAID levels 0, 1, 5, 10, and 50
• A RAID 730-8i 1G Cache SAS/SATA adapter that supports JBOD mode and RAID levels 0, 1, 5, 10, and 50
• A RAID 730-8i 2G Flash SAS/SATA adapter that supports JBOD mode and RAID levels 0, 1, 5, 6, 10, 50,
and 60
• A RAID 930-8i 2G, 930-16i 4G, or 930-24i 4G SAS/SATA adapter that supports JBOD mode and RAID
levels 0, 1, 5, 6, 10, 50, and 60
7
Summary of Contents for ThinkSystem ST550
Page 1: ...ThinkSystem ST550 Setup Guide Machine Types 7X09 and 7X10 ...
Page 4: ...ii ThinkSystem ST550 Setup Guide ...
Page 60: ...56 ThinkSystem ST550 Setup Guide ...
Page 114: ...110 ThinkSystem ST550 Setup Guide ...
Page 122: ...118 ThinkSystem ST550 Setup Guide ...
Page 130: ...126 ThinkSystem ST550 Setup Guide ...
Page 132: ...128 ThinkSystem ST550 Setup Guide ...
Page 135: ......
Page 136: ......