8. Remove the four screws
1
at the rear of the chassis and the two screws
2
on the metal clip at the
front of the power distribution board and cage assembly. Then, push the power distribution board and
cage assembly from the rear until it is released from the metal retaining tab
3
. Then, carefully lift the
power distribution board and cage assembly out of the chassis.
1
Figure 82. Removing the power distribution board and cage assembly
9. Touch the static-protective package that contains the new power distribution board and cage assembly
to any unpainted surface on the outside of the server. Then, remove the new power distribution board
and cage assembly from the package.
128
ThinkServer TS440 Hardware Maintenance Manual
Summary of Contents for ThinkServer TS440 70AL
Page 1: ...ThinkServer TS440 Hardware Maintenance Manual Machine Types 70AL 70AM 70AN and 70AQ ...
Page 16: ...4 ThinkServer TS440 Hardware Maintenance Manual ...
Page 18: ...6 ThinkServer TS440 Hardware Maintenance Manual ...
Page 41: ...Figure 14 3 5 inch hot swap hard disk drive status LEDs Chapter 3 Product overview 29 ...
Page 58: ...46 ThinkServer TS440 Hardware Maintenance Manual ...
Page 76: ...64 ThinkServer TS440 Hardware Maintenance Manual ...
Page 188: ...176 ThinkServer TS440 Hardware Maintenance Manual ...
Page 201: ......
Page 202: ......