10. Align the top edge of the EMI-protective panel with the top side of the hard-disk-drive cage, and then
pivot the EMI-protective panel down until it snaps into position.
Figure 57. Installing the EMI-protective panel
11. Disconnect the SATA cable for the removed non-hot-swap hard disk drive from the system board and
save the cable for future use.
12. Close and lock the front door.
13. If you are instructed to return the old non-hot-swap hard disk drive, follow all packaging instructions and
use any packaging materials that are supplied to you for shipping.
What to do next:
• To work with another piece of hardware, go to the appropriate section.
• To complete the removal procedure, go to “Completing the parts replacement” on page 163. Then, you
might need to reconfigure RAID for your server. See “Configuring RAID” on page 57.
Installing or replacing an internal RDX drive
Attention:
Do not open your server or attempt any repair before reading and understanding “Safety information”
on page iii and “Guidelines” on page 65.
Before you begin, print all the related instructions or ensure that you can view the PDF version on another
computer for reference.
• The internal RDX drive must be installed in the upper optical drive bay.
• Depending on the model, your server might look slightly different from the illustrations in this topic.
• Use any documentation that comes with the RDX drive and follow those instructions in addition to
the instructions in this topic.
Chapter 6
.
Installing, removing, or replacing hardware
103
Summary of Contents for ThinkServer TS440 70AL
Page 1: ...ThinkServer TS440 Hardware Maintenance Manual Machine Types 70AL 70AM 70AN and 70AQ ...
Page 16: ...4 ThinkServer TS440 Hardware Maintenance Manual ...
Page 18: ...6 ThinkServer TS440 Hardware Maintenance Manual ...
Page 41: ...Figure 14 3 5 inch hot swap hard disk drive status LEDs Chapter 3 Product overview 29 ...
Page 58: ...46 ThinkServer TS440 Hardware Maintenance Manual ...
Page 76: ...64 ThinkServer TS440 Hardware Maintenance Manual ...
Page 188: ...176 ThinkServer TS440 Hardware Maintenance Manual ...
Page 201: ......
Page 202: ......