Figure 15. 2.5-inch hot-swap hard-disk-drive status LEDs
1
Hard-disk-drive activity LED
2
Hard-disk-drive RAID status LED
Description
Off
Off
The hard disk drive has failed or is
not present.
On, green
Off
The hard disk drive is present but not
in use.
Blinking, green
Off
The hard disk drive is active and data
is being transferred.
On, green
Blinking rapidly (about four flashes
per second), amber
The RAID controller is locating the
hard disk drive.
On, green
On, amber
The RAID array has failed and cannot
recover.
Blinking, green
Blinking slowly (about one flash per
second), amber
The hard disk drive is being rebuilt.
RAID card
This topic provides information to help you locate the connectors on a RAID card if a RAID card is installed in
the PCI-E slot 1 on the system board. See “System board components” on page 39.
30
ThinkServer TS440 Hardware Maintenance Manual
Summary of Contents for ThinkServer TS440 70AL
Page 1: ...ThinkServer TS440 Hardware Maintenance Manual Machine Types 70AL 70AM 70AN and 70AQ ...
Page 16: ...4 ThinkServer TS440 Hardware Maintenance Manual ...
Page 18: ...6 ThinkServer TS440 Hardware Maintenance Manual ...
Page 41: ...Figure 14 3 5 inch hot swap hard disk drive status LEDs Chapter 3 Product overview 29 ...
Page 58: ...46 ThinkServer TS440 Hardware Maintenance Manual ...
Page 76: ...64 ThinkServer TS440 Hardware Maintenance Manual ...
Page 188: ...176 ThinkServer TS440 Hardware Maintenance Manual ...
Page 201: ......