CAUTION:
Hazardous moving parts. Keep fingers and other body parts away.
Before you begin, print all the related instructions or ensure that you can view the PDF version on another
computer for reference.
Note:
Depending on the model, your server might look slightly different from the illustrations in this topic.
To replace the front system fan 1, do the following:
1. Remove all media from the drives and turn off all attached devices and the server. Then, disconnect all
power cords from electrical outlets and disconnect all cables that are connected to the server.
2. Remove the server cover. See “Removing the server cover” on page 67.
3. Locate the front system fan 1. See “Server components” on page 23.
4. Disconnect the front system fan 1 cable from the system fan 1 connector on the system board. See
“System board components” on page 39.
5. Press the two tabs of the front system fan 1 towards each other until the two tips
1
are aligned with the
corresponding holes in the chassis. Then, carefully slide the front system fan 1 out of the chassis.
Figure 101. Removing the front system fan 1
6. Touch the static-protective package that contains the new front system fan 1 to any unpainted surface
on the outside of the server. Then, remove the new front system fan 1 from the package.
Chapter 6
.
Installing, removing, or replacing hardware
145
Summary of Contents for ThinkServer TS440 70AL
Page 1: ...ThinkServer TS440 Hardware Maintenance Manual Machine Types 70AL 70AM 70AN and 70AQ ...
Page 16: ...4 ThinkServer TS440 Hardware Maintenance Manual ...
Page 18: ...6 ThinkServer TS440 Hardware Maintenance Manual ...
Page 41: ...Figure 14 3 5 inch hot swap hard disk drive status LEDs Chapter 3 Product overview 29 ...
Page 58: ...46 ThinkServer TS440 Hardware Maintenance Manual ...
Page 76: ...64 ThinkServer TS440 Hardware Maintenance Manual ...
Page 188: ...176 ThinkServer TS440 Hardware Maintenance Manual ...
Page 201: ......
Page 202: ......