• For 2.5-inch-drive server models that have an AnyRAID adapter installed with an air duct
Loosen the screw that secures the AnyRAID-adapter air duct. Then, lift it in the direction as shown
until you can completely remove it.
Note:
The screw is an integrated part of the AnyRAID-adapter air duct. Do not try to remove the
screw from the AnyRAID-adapter air duct.
Figure 128. Removing the AnyRAID-adapter air duct for server models with 2.5-inch drives
8. Loosen the two screws that secure the AnyRAID adapter. Then, grasp the AnyRAID adapter by its edges
and carefully pull it out of the AnyRAID-adapter slots on the backplane.
Notes:
• The AnyRAID adapter fits tightly into the AnyRAID-adapter slots. If necessary, alternatively move
each side of the AnyRAID adapter a small and equal amount until it is removed from the connectors.
• The two screws are integrated parts of the AnyRAID adapter. Do not try to remove the two screws
from the AnyRAID adapter.
Figure 129. Removing the AnyRAID adapter