4. Remove the cooling shroud. See “Removing the cooling shroud” on page 75.
5. Remove any parts and disconnect any cables that might impede your operation.
6. Locate the M.2 storage module and disconnect the cables. See “Server components” on page 25.
7. Press the two release tabs
1
and lift the M.2 storage module out of the chassis.
Note:
Carefully handle the M.2 storage module by its edges.
Figure 71. Removing the M.2 storage module
8. Remove the screw that secures the M.2 storage drive. Then, remove the M.2 storage drive.
Figure 72. Removing the M.2 storage drive
9. If you are instructed to return the old M.2 storage module, follow all packaging instructions and use any
packaging materials that are supplied to you for shipping.
What to do next:
• To work with another piece of hardware, go to the appropriate section.
• To complete the removal procedure, go to “Completing the parts replacement” on page 180.
117