![Lenovo ThinkServer TD350 User Manual And Hardware Maintenance Manual Download Page 163](http://html.mh-extra.com/html/lenovo/thinkserver-td350/thinkserver-td350_user-manual-and-hardware-maintenance-manual_203018163.webp)
b. Disconnect the power cord from the failing hot-swap redundant power supply. Then, press the
release tab
1
and pull the handle
2
at the same time to slide the failing hot-swap redundant
power supply out of the chassis.
Figure 113. Removing a hot-swap redundant power supply
2. Touch the static-protective package that contains the new hot-swap redundant power supply to any
unpainted surface on the outside of the server. Then, remove the new hot-swap redundant power
supply from the package.
3. Note the orientation of the new hot-swap redundant power supply, and then slide it into the chassis until
it snaps into position.
Figure 114. Installing a hot-swap redundant power supply
4. Connect the power cord to the power cord connector on the new power supply. Then, check the
status LEDs near the power cord connector. For information about the status LEDs, see “Power supply
status LEDs” on page 32.
149
Summary of Contents for ThinkServer TD350
Page 14: ...xii ThinkServer TD350 User Guide and Hardware Maintenance Manual ...
Page 18: ...4 ThinkServer TD350 User Guide and Hardware Maintenance Manual ...
Page 20: ...6 ThinkServer TD350 User Guide and Hardware Maintenance Manual ...
Page 206: ...192 ThinkServer TD350 User Guide and Hardware Maintenance Manual ...
Page 213: ...China RoHS Appendix A Notices 199 ...
Page 224: ...210 ThinkServer TD350 User Guide and Hardware Maintenance Manual ...
Page 225: ......
Page 226: ......