Page 372
MegaRAID SAS Software User Guide
Chapter 11: Using MegaRAID® Advanced Software
|
SafeStore Encryption Services
Import or clear the foreign configuration. If you select
Import
, all drives that were
pulled
before
the virtual drive became offline will be imported and then
automatically rebuilt. Automatic rebuilds will occur in redundant virtual drives.
Scenario #4: If the drives in a non-redundant virtual drive are removed, the
controller considers the drives to have foreign configurations.
Import or clear the foreign configuration. No rebuilds will occur after the import
operation because there is no redundant data to rebuild the drives.