Page 18
MegaRAID SAS Software User Guide
Chapter 1: Overview
|
Technical Support
1.7.1
Valid Drive Mix Configurations
with HDDs and CacheCade – SSD
Caching software
You can allow a virtual drive to consist of both CacheCade – SSD Caching software and
HDDs. For virtual drives that have both CacheCade – SSD Caching software and HDDs,
you can choose whether to mix SAS drives and SATA drives on the CacheCade – SSD
Caching software devices.
You can choose whether to allow a virtual drive to consist of both CacheCade – SSD
Caching software devices and HDDs. For a virtual drive that consists of CacheCade –
SSD Caching software only, you can choose whether to allow SAS CacheCade – SSD
Caching software drives and SATA CacheCade – SSD Caching software drives in that
virtual drive. For virtual drives that have both CacheCade – SSD Caching software and
HDDs, you can choose whether to mix SAS and SATA HDD drives with SAS and SATA
CacheCade – SSD Caching software devices in various combinations.
Table 1
lists the valid drive mix configurations you can use when you create virtual
drives and allow HDD and CacheCade – SSD Caching software mixing. The valid drive
mix configurations are based on manufacturer settings.
NOTE:
Only one of the valid configurations listed in
Table 1
is allowed based on your
controller card manufacturing settings.
NOTE:
The valid drive mix also applies to hot spares. For hot spare information, see
Section 2.4.12,
Hot Spares, on page 28
.
Table 1:
Valid Drive Mix Configurations
#
Valid Drive Mix Configurations
1.
SAS HDD with SAS SDD (SAS-only configuration)
2.
SATA HDD with SATA CacheCade – SSD Caching software (SATA-only configuration)
3.
SAS HDD with a mix of SAS and SATA CacheCade – SSD Caching software (a SATA HDD
cannot be added)
4.
SATA HDD with a mix of SAS and SATA CacheCade – SSD Caching software (a SAS HDD
cannot be added)
5.
SAS CacheCade – SSD Caching software with a mix of SAS and SATA HDD (a SATA
CacheCade – SSD Caching software cannot be added)
6.
SATA CacheCade – SSD Caching software with a mix of SAS and SATA HDD (a SAS
CacheCade – SSD Caching software cannot be added)
7.
A mix of SAS and SATA HDD with a mix of SAS and SATA CacheCade – SSD Caching
software
8.
A CacheCade – SSD Caching software cannot be added to a HDD, but a SAS/SATA mix is
allowed.
Summary of Contents for ThinkServer RD330
Page 1: ...ThinkServer MegaRAID SAS Software User Guide ...
Page 12: ...Page 12 MegaRAID SAS Software User Guide Table of Contents ...
Page 20: ...Page 20 MegaRAID SAS Software User Guide Chapter 1 Overview Technical Support ...
Page 294: ...Page 294 MegaRAID SAS Software User Guide Chapter 8 Configuration Deleting a Virtual Drive ...
Page 386: ...Page 386 MegaRAID SAS Software User Guide Appendix A Events and Messages Event Messages ...
Page 400: ......
Page 401: ......