Page 190
MegaRAID SAS Software User Guide
Chapter 5: MegaRAID Command Tool
|
Battery Backup Unit-Related Properties
5.11.3
Display BBU Capacity
Use the command in the following table to display the BBU capacity for the selected
controller(s).
5.11.4
Display BBU Design
Parameters
Use the command in the following table to display BBU design parameters for the
selected controller(s).
Table 55: Display BBU Capacity Information
Convention
MegaCli -AdpBbuCmd -GetBbuCapacityInfo
–aN|-a0,1,2|-aALL
Description
Displays BBU capacity information. The information displays in the following
format:
BBU Capacity Info for Adapter: x
Relative State of Charge: xx%
Absolute State of Charge: xx%
Remaining Capacity: xx mAh
Full Charge Capacity: xx mAh
Run Time to Empty: xxx Min
Average Time to Empty: xxx Min
Average Time to Full: xxx Min
Cycle Count: xx
Max Error: xx%
Table 56: Display BBU Design Parameters
Convention
MegaCli -AdpBbuCmd -GetBbuDesignInfo
–aN|-a0,1,2|-aALL
Description
Displays information about the BBU design parameters. The information
displays in the following formats:
BBU Design Info for Adapter: x
Date of Manufacture: mm/dd, yyyy
Design Capacity: xxx mAh
Design Voltage: mV
Serial Number: 0xhhhh
Pack Stat Configuration: 0xhhhh
Manufacture Name: XXXXXX(String)
Device Name: XXXXXX(String)
Device Chemistry: XXXXXX(String)
Summary of Contents for ThinkServer RD330
Page 1: ...ThinkServer MegaRAID SAS Software User Guide ...
Page 12: ...Page 12 MegaRAID SAS Software User Guide Table of Contents ...
Page 20: ...Page 20 MegaRAID SAS Software User Guide Chapter 1 Overview Technical Support ...
Page 294: ...Page 294 MegaRAID SAS Software User Guide Chapter 8 Configuration Deleting a Virtual Drive ...
Page 386: ...Page 386 MegaRAID SAS Software User Guide Appendix A Events and Messages Event Messages ...
Page 400: ......
Page 401: ......