Page 245
MegaRAID SAS Software User Guide
Chapter 6: MegaRAID Storage Manager Overview and Installation
|
Installing and Configur-
ing an SNMP Agent
The following commands are used to start, stop, restart, and check the status of the SAS
SNMP Agent daemon:
Start:
#/etc/init.d/lsi_mrdsnmpd start
Stop:
#/etc/init.d/lsi_mrdsnmpd stop
Restart:
#/etc/init.d/lsi_mrdsnmpd restart
Status:
#/etc/init.d/lsi_mrdsnmpd status
6.7.3.5
Configuring snmpd.conf
By default, SNMP queries (walk, get) can be executed from any remote machine
without any changes to the
snmpd.conf
file. To quickly add a new community and
client access, perform the following steps:
1. Stop the SMA service by executing the following command:
# svcadm disable svc:/application/management/sma:default
2. Add read-only and read-write community names.
a. Add a read-only community name and client/hostname/ipaddress under
"SECTION: Access Control Setup" in the
/etc/sma/snmp/snmpd.conf
file, as
shown in the following excerpt:
#################################################
# SECTION: Access Control Setup
# This section defines who is allowed to talk to your
# running SNMP Agent.
# rocommunity: a SNMPv1/SNMPv2c read-only access
# community name
# arguments: community
# [default|hostname|network/bits] [oid]
# rocommunity snmpclient 172.28.157.149
#################################################
b. Add a readwrite community name and client/hostname/ipaddress under
"SECTION: Access Control Setup" in
/etc/sma/snmp/snmpd.conf
file, as
shown in the following excerpt:
#################################################
# SECTION: Access Control Setup
# This section defines who is allowed to talk to your
# running
# snmp agent.
# rocommunity: a SNMPv1/SNMPv2c read-only access
# community name
# arguments: community
# [default|hostname|network/bits] [oid]
# rwcommunity snmpclient 172.28.157.149
#################################################
3. Start the SMA service by using the following command:
# svcadm enable svc:/application/management/sma:default
NOTE:
Refer to the command
man snmpd.conf
for more information about
configuring the
snmpd.conf
file.
Summary of Contents for ThinkServer RD330
Page 1: ...ThinkServer MegaRAID SAS Software User Guide ...
Page 12: ...Page 12 MegaRAID SAS Software User Guide Table of Contents ...
Page 20: ...Page 20 MegaRAID SAS Software User Guide Chapter 1 Overview Technical Support ...
Page 294: ...Page 294 MegaRAID SAS Software User Guide Chapter 8 Configuration Deleting a Virtual Drive ...
Page 386: ...Page 386 MegaRAID SAS Software User Guide Appendix A Events and Messages Event Messages ...
Page 400: ......
Page 401: ......