Page 163
MegaRAID SAS Software User Guide
Chapter 4: WebBIOS Configuration Utility
|
Managing Configurations
3. Select
AdvOpers
under the
Operations
heading.
The Advanced Operations screen appears, as shown in
Figure 114
.
Figure 114: Advanced Operations Screen
4. Select either
Change RAID Level
or
Change RAID Level and Add Drive
.
— If you select
Change RAID Level
, change the RAID level from the drop-down
menu.
— If you select
Change RAID Level and Add Drive
, change the RAID level from
the drop-down menu and then select one or more drives to add from the list of
drives.
The available RAID levels are limited, based on the current RAID level of the virtual
drive plus the number of drives available.
5. Click
Go
.
6. When the message appears, confirm that you want to migrate the RAID level of the
virtual drive.
A reconstruction operation begins on the virtual drive. You must wait until the
reconstruction is completed before you perform any other tasks in the WebBIOS CU.
4.12.9
New Drives Attached to a
MegaRAID Controller
When you insert a new drive on a MegaRAID system, if the inserted drive does not
contain valid DDF metadata, the drive displays as JBOD for MegaRAID Entry level
controllers, such as the SAS 9240-4i/8i. If the drive does contain valid DDF metadata, its
drive state is Unconfigured Good.
Summary of Contents for ThinkServer RD330
Page 1: ...ThinkServer MegaRAID SAS Software User Guide ...
Page 12: ...Page 12 MegaRAID SAS Software User Guide Table of Contents ...
Page 20: ...Page 20 MegaRAID SAS Software User Guide Chapter 1 Overview Technical Support ...
Page 294: ...Page 294 MegaRAID SAS Software User Guide Chapter 8 Configuration Deleting a Virtual Drive ...
Page 386: ...Page 386 MegaRAID SAS Software User Guide Appendix A Events and Messages Event Messages ...
Page 400: ......
Page 401: ......