Page 184
MegaRAID SAS Software User Guide
Chapter 5: MegaRAID Command Tool
|
Controller Property-Related Options
Table 41: Set Controller Properties
Convention
MegaCli –AdpSetProp {CacheFlushInterval –val}|{RebuildRate -val}| {PatrolReadRate
–val}|{BgiRate –val}|{CCRate –val}| {ReconRate –val}| {SpinupDriveCount
–val}|{SpinupDelay –val}|{CoercionMode –val} | {ClusterEnable
–val}|{PredFailPollInterval –val}| {BatWarnDsbl –val}| {EccBucketSize
–val}|{EccBucketLeakRate –val}|{AbortCCOnError –val}|AlarmEnbl | AlarmDsbl |
AlarmSilence |{SMARTCpyBkEnbl –val} |
-AutoDetectBackPlaneDsbl | -CopyBackDsbl | -LoadBalanceMode
| NCQEnbl | NCQDsbl | {SSDSMARTCpyBkEnbl -val} | {MaintainPdFailHistoryEnbl -val} |
{EnblSpinDownUnConfigDrvs -val} | AutoEnhancedImportEnbl | AutoEnhancedImportDsbl |
{-UseFDEOnlyEncrypt -val} | {-PrCorrectUncfgdAreas -val} | -aN| -a0,1,2|-aALL
Description
Sets the properties on the selected controller(s). The possible settings are:
CacheFlushInterval
: Cache flush interval in seconds. Values: 0 to 255.
RebuildRate
: Rebuild rate. Values: 0 to 100.
PatrolReadRate
: Patrol read rate. Values: 0 to 100.
BgiRate
: Background initilization rate. Values: 0 to 100.
CCRate
: Consistency check rate. Values: 0 to 100.
ReconRate
: Reconstruction rate. Values: 0 to 100.
SpinupDriveCount
: Max number of drives to spin up at one time. Values: 0 to 255.
SpinupDelay
: Number of seconds to delay among spinup groups. Values: 0 to 255.
CoercionMode
: Drive capacity Coercion mode. Values: 0 - None, 1 - 128 MB, 2 - 1 GB.
ClusterEnable
: Cluster is enabled or disabled. Values: 0 - Disabled, 1 - Enabled.
PredFailPollInterval
: Number of seconds between predicted fail polls. Values: 0 to 65535.
BatWarnDsbl
: Disable warnings for missing battery or missing hardware. Values: 0 - Enabled, 1 - Disabled.
EccBucketSize
: Size of ECC single-bit-error bucket. Values: 0 to 255.
EccBucketLeakRate
: Leak rate (in minutes) of ECC single-bit-error bucket. Values: 0 to 65535.
AbortCCOnError
:
AlarmEnbl
: Set alarm to Enabled.
AlarmDsbl
: Set alarm to Disabled.
AlarmSilence
: Silence an active alarm.
SMARTCpyBkEnbl
: Enable copyback operation on Self-Monitoring Analysis and Reporting Technology (SMART) errors.
Copyback is initiated when the first SMART error occurs on a drive that is part of a virtual drive.
AutoDetectBackPlaneDsbl
: Detect automatically if the backplane has been disabled.
CopyBackDsbl
: Disable or enable the copyback operation.
LoadBalanceMode
: Disable or enable the load balancing mode.
NCQEnbl
:
Enable the native command queueing.
NCQDsbl
:
Disable the native command queueing.
SSDSMARTCpyBkEnbl
:
Enable copyback operation on Self-Monitoring Analysis and Reporting Technology (SMART) errors
on a CacheCade software. Copyback is initiated when the first SMART error occurs on a SSD that is part of a virtual drive.
MaintainPdFailHistoryEnbl
:
Enable maintenance of the history of a failed drive.
EnblSpinDownUnConfigDrvs
:
Enable spindown of unconfigured drives.
AutoEnhancedImportEnbl
:
Enable the automatic enhanced import of foreign drives.
AutoEnhancedImportDsbl
:
Disable the automatic enhanced import of foreign drives.
UseFDEOnlyEncrypt
:
Use encryption on FDE drives only.
PrCorrectUncfgdAreas
:
Summary of Contents for ThinkServer RD330
Page 1: ...ThinkServer MegaRAID SAS Software User Guide ...
Page 12: ...Page 12 MegaRAID SAS Software User Guide Table of Contents ...
Page 20: ...Page 20 MegaRAID SAS Software User Guide Chapter 1 Overview Technical Support ...
Page 294: ...Page 294 MegaRAID SAS Software User Guide Chapter 8 Configuration Deleting a Virtual Drive ...
Page 386: ...Page 386 MegaRAID SAS Software User Guide Appendix A Events and Messages Event Messages ...
Page 400: ......
Page 401: ......