Figure 36. DIMM removal
Step 1. Open the retaining clips on each end of the DIMM slot.
Attention:
To avoid breaking the retaining clips or damaging the DIMM slots, handle the clips
gently.
Step 2. Grasp the DIMM at both ends and carefully lift it up to remove it from the slot.
After removing a DIMM:
1. Install a DIMM filler or a new DIMM to cover the slot. See “Install a DIMM” on page 74.
2. If you are instructed to return the old DIMM, follow all packaging instructions and use any packaging
materials that are provided.
DIMM installation rules
DIMMs must be installed in a specific order based on the memory configuration that you implement on your
server.
Your server has 24 DIMM slots and it has the following features:
• Each slot supports 8 GB, 16 GB, and 32 GB DDR4 RDIMMs with Error Checking and Correcting (ECC)
technology.
• Each slot supports 64 GB DDR4 LRDIMMs with ECC technology.
• Your server supports up to 12 DIMMs when one processor is installed, and up to 24 DIMMs when two
processors are installed.
• The minimum system memory is 8 GB (only one processor installed and only one 8 GB RDIMM installed in
the CPU1 DIMM5 slot).
• The maximum system memory is as follows:
– 768 GB using RDIMMs (two processors installed and one 32 GB RDIMM installed in each of the 24
DIMM slots)
– 1.5 TB using LRDIMMs (two processors installed and one 64 GB LRDIMM installed in each of the 24
DIMM slots)
.
Hardware replacement procedures
69
Summary of Contents for ThinkAgile HX2320 Appliance
Page 4: ...ii User Guide for ThinkAgile HX2320 Appliance and HX2321 Node ...
Page 16: ...12 User Guide for ThinkAgile HX2320 Appliance and HX2321 Node ...
Page 32: ...28 User Guide for ThinkAgile HX2320 Appliance and HX2321 Node ...
Page 38: ...34 User Guide for ThinkAgile HX2320 Appliance and HX2321 Node ...
Page 86: ...82 User Guide for ThinkAgile HX2320 Appliance and HX2321 Node ...
Page 90: ...86 User Guide for ThinkAgile HX2320 Appliance and HX2321 Node ...
Page 92: ...88 User Guide for ThinkAgile HX2320 Appliance and HX2321 Node ...
Page 94: ...90 User Guide for ThinkAgile HX2320 Appliance and HX2321 Node ...
Page 96: ...92 User Guide for ThinkAgile HX2320 Appliance and HX2321 Node ...
Page 99: ......
Page 100: ......