v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v
See the
Hardware Maintenance Manual
to determine which components are customer replaceable units (CRUs)
and which components are field replaceable units (FRUs).
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
v
Go to the Lenovo support Web site at http://www.lenovo.com/support to check for technical information, hints,
tips, or new device drivers.
Error code
Description
Action
0050001
DIMM disabled.
1.
If the server fails the POST memory test, reseat
the DIMMs.
2.
Remove and replace any DIMM for which the
associated error LED is lit (see “Replacing or
installing a memory module (DIMM)” on page
32).
3.
Run the Setup utility to enable all the DIMMs.
4.
Run the DSA Preboot memory test (see
“Diagnostic tools” on page 113).
0051003
Uncorrectable DIMM error
1.
If the server failed the POST memory test, reseat
the DIMMs.
2.
Remove and replace any DIMM for which the
associated error LED is lit (see “Replacing or
installing a memory module (DIMM)” on page
32).
3.
Run the Setup utility to enable all the DIMMs.
4.
Run the DSA Preboot memory test (see
“Diagnostic tools” on page 113).
0051006
DIMM mismatch detected
Make sure that the DIMMs match and are installed in
the correct sequence (see “Installing a memory
module” on page 36).
0051009
No memory detected.
1.
Make sure that the server contains DIMMs.
2.
Reseat the DIMMs.
3.
Install DIMMs in the correct sequence (see
“Installing a memory module” on page 36).
005100A
No usable memory detected.
1.
Make sure that the server contains DIMMs.
2.
Reseat the DIMMs.
3.
Install DIMMs in the correct sequence (see
“Installing a memory module” on page 36).
4.
Clear CMOS memory to re-enable all the memory
connectors (see Table 4 on page 20).
0058001
PFA threshold exceeded
1.
Update the server firmware to the latest level (see
“Updating the firmware” on page 103).
2.
Reseat the DIMMs and run the memory test (see
“Diagnostic tools” on page 113).
3.
Replace the failing DIMM, which is indicated by
a lit LED on the system board.
116
ThinkServer RS210, Types 6531, 6532, 6533, and 6534: Installation and User Guide
Summary of Contents for 653417U
Page 1: ...Installation and User Guide ThinkServer RS210 Machine Types 6531 6532 6533 and 6534 ...
Page 2: ......
Page 3: ...ThinkServer RS210 Types 6531 6532 6533 and 6534 Installation and User Guide ...
Page 8: ...vi ThinkServer RS210 Types 6531 6532 6533 and 6534 Installation and User Guide ...
Page 16: ...xiv ThinkServer RS210 Types 6531 6532 6533 and 6534 Installation and User Guide ...
Page 20: ...4 ThinkServer RS210 Types 6531 6532 6533 and 6534 Installation and User Guide ...
Page 22: ...6 ThinkServer RS210 Types 6531 6532 6533 and 6534 Installation and User Guide ...
Page 40: ...24 ThinkServer RS210 Types 6531 6532 6533 and 6534 Installation and User Guide ...
Page 66: ...50 ThinkServer RS210 Types 6531 6532 6533 and 6534 Installation and User Guide ...
Page 128: ...112 ThinkServer RS210 Types 6531 6532 6533 and 6534 Installation and User Guide ...
Page 160: ...144 ThinkServer RS210 Types 6531 6532 6533 and 6534 Installation and User Guide ...
Page 164: ...148 ThinkServer RS210 Types 6531 6532 6533 and 6534 Installation and User Guide ...
Page 173: ...Chinese Class A warning statement Korean Class A warning statement Appendix B Notices 157 ...
Page 174: ...158 ThinkServer RS210 Types 6531 6532 6533 and 6534 Installation and User Guide ...
Page 179: ......
Page 180: ...Printed in USA ...