DEFROST CONTROL BOARD

FIGURE 13

24V

TERMINAL

STRIP

HIGH PRESSURE

SWITCH

TERMINALS

S4

S5

PRESSURE SWITCH

WIRING CONNECTIONS

High

Pressure

Switch

(Factory−wired)

OPTIONAL

PRESSURE

SWITCH

TERMINALS

(Remove factory−

installed jumper

to install

pressure switch.)

Optional

Pressure

Switch

(Field−provided

and installed −− 

jumper removed)

AMBIENT

THERMISTER

TERMINALS

SERVICE

LIGHT

TERMINALS

DIAGNOSTIC

LEDs

DEFROST

INTERVAL

TIMING PINS

CC

Y

IV−REFRIGERANT SYSTEM

A−Plumbing

An expansion/check valve is used in parallel in the liquid
line.  The check valve is closed when the unit is in heating
mode to force refrigerant through the expansion valve.
The check valve is open when the unit is in cooling mode.

Field refrigerant piping consists of liquid and vapor lines
from the outdoor unit (sweat connections). Use Lennox
L10 (flare) or L15 (sweat) series line sets as shown in table
7 or field fabricated refrigerant lines. Refer to the piping
section of the Lennox Unit Information Service Manual for
proper size, type and application of field-fabricated lines.

If refrigerant tubes are routed through a wall, seal and iso-
late the opening so vibration is not transmitted to the build-
ing.

NOTE − Line length should be no greater than 50 feet (15.2
m).  Select line set diameters from table 1 to ensure oil re-
turn to compressor.

TABLE 7

REFRIGERANT LINE SET KITS

HP27

UNIT

LIQUID

VAPOR

L10

LINE

LINE

LINE SETS

−024
−030

3/8 in.

3/4 in.

L10−41

(9.5 mm) (19.1 mm)

20 ft. − 50 ft.

(6.1 m−15.2 m)

−042

3/8 in.

(9.5 mm)

7/8 in.

(22.2 mm)

L10−65

30 ft. − 50 ft.

(9.1 m − 15.2 m)

L15

LINE SETS

L15−41

15 ft. − 50 ft.

(4.5 m−15.2  m)

L15−65

15 ft. − 50 ft.

(4.5 m−15.2  m)

−036

Separate discharge and suction service ports are pro-
vided at the compressor for connection of gauge manifold
during charging procedure. Figure 14 and 15  show HP27
gauge manifold connections.

Summary of Contents for HP27?024

Page 1: ...22 866 22 866 22 866 22 866 Diameter in mm No of blades 24 610 3 24 610 3 24 610 3 24 610 3 C d Motor hp W 1 10 75 1 10 75 1 10 75 1 10 75 Condenser Fan Cfm L s 2800 1320 2800 1320 2800 1320 2800 132...

Page 2: ...it is in constant contact with discharge gas FIGURE 2 SCROLL FORM FIGURE 3 STATIONARY SCROLL ORBITING SCROLL DISCHARGE SUCTION CROSS SECTION OF SCROLLS TIPS SEALED BY DISCHARGE PRESSURE DISCHARGE PRE...

Page 3: ...ated in the unit control box for making thermostat wiring connections refer to figure 6 C Compressor Table 1 shows the specifications of compressors B1 used in HP27 series units TABLE 1 Unit Phase LRA...

Page 4: ...ee wiring diagrams for specific unit The con tactor is energized by indoor thermostat terminal Y when thermostat demand is present DANGER Electric Shock Hazard May cause injury or death Disconnect all...

Page 5: ...unit control box see figure 6 Table 3 shows the ratings of the dual ca pacitor TABLE 3 HP27 DUAL CAPACITOR RATING UNITS FAN MFD HERM MFD VAC HP27 024 4 40 370 HP27 030 4 40 370 HP27 036 4 45 370 HP27...

Page 6: ...fety Circuits The defrost control incorporates a safety circuit that allows the application of an additional pressure switch The unit s high pressure switch S4 is factory wired into this circuit See f...

Page 7: ...continuous line cycles If a system protection switch opens while the Y1 OUT cir cuit is energized the timed off control will initiate a 5 min ute delay when the pressure switch closes The timed off co...

Page 8: ...ion During normal operation the control board continuously monitors the system operation mode heating cooling the outdoor ambient temperature the outdoor coil temper ature and compressor run time to d...

Page 9: ...rol board initiates a defrost cycle based on either frost detection or time Frost Detection If the compressor runs longer than 34 minutes and the actual difference between the clear coil and frosted c...

Page 10: ...en the unit will remain in Heating Mode Remove and reapply test jumper to return to test mode if desired If sensor circuits are closed the unit will go into Defrost Mode Defrost mode ends Unit enters...

Page 11: ...on will not function again until the jumper is removed and re ap plied Time Delay The timed off delay is five minutes long The delay helps protect the compressor from short cycling in case the pow er...

Page 12: ...Use Lennox L10 flare or L15 sweat series line sets as shown in table 7 or field fabricated refrigerant lines Refer to the piping section of the Lennox Unit Information Service Manual for proper size...

Page 13: ...APOR LINE VALVE SUCTION SERVICE PORT TO HCFC 2 2 DRUM HIGH PRESSURE LIMIT THERMOME TER WELL ACCUMULATOR FIGURE 15 NOTE Use gauge ports on vapor line valve and liquid valve for evacuating refrigerant l...

Page 14: ...LVE VALVE CLOSED VALVE FRONT SEATED FIELD SIDE UNIT SIDE To Access Schrader Port 1 Remove access panel 2 Remove service port cap with an adjustable wrench 3 Connect gauge to the service port 4 When te...

Page 15: ...uge to center port of gauge manifold With both manifold service valves open start pump and evac uate indoor coil and refrigerant lines IMPORTANT A temperature vacuum gauge mercury vacuum U tube or the...

Page 16: ...Below 60 F 16 C NOTE It may be necessary to restrict air flow in order to reach liquid pressures in the 200 250 psig range which are required for checking charge Block equal sections of air intake pa...

Page 17: ...ason the system should be cleaned as follows A Outdoor Unit 1 Clean and inspect outdoor coil Coil may be flushed with a water hose 2 Visually inspect all connecting lines joints and coils for evidence...

Page 18: ...ELD WIRING DIAGRAM HP27 WITH INDOOR UNIT 1 2 3 THERMOSTAT HEAT ANTICIPATION SET TING 4 AMP ELECTRIC HEAT WHEN TWO STAGE THERMOSTAT IS USED CONNECT SECOND STAGE HEAT BULB TO TER MINAL W2 AND REMOVE JUM...

Page 19: ...Page 19 C Diagram HP27 1 208 230 Volt 1 2 3 4 5 6 7 8...

Page 20: ...Page 20 D Diagram HP27 6 208 230 Volt 1 2 3 4 5 6 7 8...

Page 21: ...Page 21 E Diagram HP27 7 208 230 Volt 1 2 3 4 5 6 7 8...

Page 22: ...Page 22 F Diagram HP27 7 208 230 Volt 1 2 3 4 5 6 7 8...

Page 23: ...ODE 9 During heating operation when outdoor coil tempera ture drops below 35 F 2 C or 42 5 5 C see de frost system description for specific unit dash number defrost switch thermostat S6 closes 10 Defr...

Reviews: