DirecDoor Installation Guide
11
Specifications
Note:
For output load capacity (watts) available for readers and strikes, refer to
Controller to readers
Reader voltage: 12 VDC
If the cable distance is:
•
Greater than 500 feet (152.4 m), but not greater/longer than
2000 feet (609.6 m), and/or current per reader greater than 150 mA:
use 20-AWG shielded cable, refer to
•
Less than 500 feet (152.4 m): use 22-AWG shielded cable.
We recommend using 20-AWG shielded cable to wire readers, DOs, and
DIs. Use plenum-rated cable for applications where cable is to be run
above the false (suspended) ceiling in the air circulation space.
Recommended:
•
Alpha Xtra Guard1® foil shield cable, non-plenum-rated
•
Belden series security and alarm cable (commercial applications
shielded), plenum-rated
Controller to DIs or
DOs
Use any cable with the desired number of individually shielded pairs.
Devices
Readers
•
Number supported: maximum of two (2) readers
•
Reader technology supported: Wiegand, F/2F, and Supervised F/2F
•
Supports keypad only and keypad/reader technology
•
Output devices maximum ratings:
•
Door DO (Reader LED) = 20 mA @ 12 VDC maximum
•
Door strike (DO) relay = 2 A @ 28 VDC or 30 VAC maximum
Strikes
Maximum current: 390 mA per strike output.
Refer to table
on page 12 for recommended strike
models and associated power requirements.
DOs
•
Number supported: maximum six (6) DOs
•
Output devices maximum ratings: six (6) DO outputs: 20 mA @ 7.5
to 12 VDC
Regulatory information
Listings
•
FCC Class A
•
UL 1076
•
UL 294
•
CE
Refer to
for more information.
Maximum Peripheral Loads
Reader/Strike
PoE
Auxiliary Power Supply
Voltage DC
12
24
12
24
Enclosure Specifications (Continued)
Summary of Contents for DirecDoor
Page 1: ...7 4 DirecDoor Installation Guide...
Page 4: ......
Page 8: ...Table of Contents 8 DirecDoor Installation Guide...
Page 14: ...Introduction 14 DirecDoor Installation Guide...
Page 19: ...DirecDoor Installation Guide 19 Mounting DirecDoor Mounting Template...
Page 22: ...Installation Planning and Mounting 22 DirecDoor Installation Guide...
Page 56: ...DDIO Interface 56 DirecDoor Installation Guide Resistances Detected by PXNplus...
Page 58: ...DO Interface 58 DirecDoor Installation Guide Wiring Output Device to DO Interface...
Page 76: ...Controller Firmware Tools 76 DirecDoor Installation Guide...
Page 79: ...DirecDoor Installation Guide 79 CE Regulatory Notice CE Regulatory Notice...