Regulatory Information
CE (European) and FCC Compliance
As of January 1, 1996, all new European Union member installations MUST be CE compliant.
To make the DirecDoor installation CE and FCC compliant, the following conditions must be met:
•
All cables connected to the DirecDoor must be shielded with shield terminated as shown in
Typical Installation Using Shielded Cable/Drain Wire
. Use #8-32 SEMS
screws provided.
•
The DirecDoor enclosure must be connected to the nearest earth ground. Refer to figure
.
•
Before connecting the network cable to connector J10, loop the cable through Ferrite provided as
shown in figure
Note:
Ferrite must be installed inside of the enclosure.