![Leica Geosystems ScanStation C10 User Manual Download Page 95](http://html.mh-extra.com/html/leica-geosystems/scanstation-c10/scanstation-c10_user-manual_1873552095.webp)
ScanStation C10/C5, Care and Transport
95
5.8
Adjustment of the Laser Plummet
The laser plummet is located in the vertical axis of the instrument. Under normal
conditions of use, the laser plummet does not need adjusting. If an adjustment is
necessary due to external influences, the instrument has to be returned to any Leica
Geosystems authorised service workshop.
Inspecting the
laser plummet
step-by-step
1. Place and secure the instrument into the tribrach and onto a tripod.
2. Using the tribrach footscrews, level the instrument with the electronic level. In
the
Main Menu
go to
Status
,
Level and Laser plummet
,
Level
.
4
2
5
6
3
360°
≤
3 mm / 1.5 m
Ø 2.5 mm / 1.5 m
C10_039