User Manual LW120
correct your setting.
The Multi-Instrument Sync Control group lets you synchronize
between multiple instruments and program phase offset between
instruments. The phase offset is applied between the leading edges of
the two instruments and is given in units of waveform points. To adjust
the Ph.
LED next to the Ph. Offset turns on. The offset value is displayed on
the digital display. You can use the dial, keyboard, or the [
↑
] [
↓
} keys
to adjust the readout to the required setting. After you modify the
reading, press Execute to update the LW120 with the new reading.
Mode
– The Mode buttons let you select between
Master
and
Slave
modes. Special cables are required to connect multiple instruments in
a daisy-chain link and the Master/Slave options w
Multi-Instruments Sync
Control
Offset parameter, click on the button below parameter. The
ill work only when
the instruments are connected properly to each other. Use the
information in Chapter 3 to find out more about multi-instruments
synchronization.
The
State
– The State button will turn the couple mode on and off.
There are two additional buttons at the right top corner of the Utility
Panel. You can close the Utility Panel by clicking on the Close key, or
return to the main panel and leave the Utility Panel in the background
if you click on the “To Main Panel” key.
System and
ArbExplorer requires certain conditions to work well with the LW120.
For example, The computer you are using must be connected to the
instrument through a known and well-defined communication link,
such as, GPIB or RS232. Not only that the instrument must be
connected properly but also, software and registers must be
your computer is running smoothly but the LW120 has problems
communicating with your computer. The System and Command Editor
dialog box has all the tools needed to make sure that th
Command Editor
set
properly for the generator to function properly. It is also possible that
e LW120 is
connected properly and that it responds correctly to machine
commands.
Invoke the System and Command Editor from the System command
at the top of the screen. Dialog box, as shown in Figure 5-10 will pop
up. There are three main functions that you can execute using this
dialog box: Set your communication link, Reset and test your
communication with the LW120 and, last but no least, send SCPI
commands to the instrument and see an immediate response.
Description of the various elements of this dialog box is given below.