F
Error code “Err1”: Door lock failure
Models
: WHWF09810M/NM
Description
: One of several conditions related to the doorlock system
Error Trigger Conditions:
1.
INTERLOCK voltage not present at U1:CN2 after doorlock pulse sent OR,
2.
INTERLOCK voltage established and lost during a wash program OR,
3.
INTELOCK voltage present after door unlock pulse sent
Recommend actions:
Use doorlock diagnostic flowchart to determine cause.
Error code “Er1A”: Door lock fail on program start
Models
: WHLFP715M/MI/NM/DC
WHLFP817M/MI/NM/DC
Error Trigger Condition:
INTERLOCK voltage not present at U1:CN1 after doorlock pulse sent
Recommend actions:
Use doorlock diagnostic flowchart to determine cause.
Error code “Er1b”: Door lock error during program execution
Models
: WHLFP715M/MI/NM/DC
WHLFP817M/MI/NM/DC
Error Trigger Conditions:
1.
INTERLOCK voltage present at U1:CN2 after doorlock pulse sent AND,
2.
INTERLOCK voltage lost during wash program.
Recommend actions:
Use doorlock diagnostic flowchart to determine cause.
Summary of Contents for CROSSOVER 2.0 Series
Page 1: ...CROSSOVER2 0 TRAINING MANUAL...
Page 2: ...CROSSOVER 2 0 SERIES W A S H E R S E R V I C E S C H O O L DOC NO 098017 EDITION 25 2018...
Page 24: ......
Page 25: ......
Page 26: ......
Page 27: ......
Page 41: ...DOOR SWITCH AND DOORLOCK DIAGNOSTIC PROCEDURE Error Codes 1 1a 1b 1c and 1d Fig 7 7...
Page 50: ...Fig 7 13 WHLFP715 WHLFP817 Wiring Diagram...
Page 67: ......