4: Configuration Using Web Manager
WiPort Embedded Wireless Device Server User Guide
34
character is carriage return.
Manual Connection:
Attempts to connect when directed by a
command string received from the serial port.
Auto Start:
Automatically connects to the remote IP address
and port after booting up.
Start Character
If Active Connect is set to
With Start Character
, enter the
start character in this field.
Modem Mode
Indicates the on-screen response type when in Modem Mode
(if
Modem Mode
is enabled). The options are:
Without Echo
Verbose Mdm Resp & Echo
Numeric Mdm Resp & Echo
Verbose Mdm Resp Only
Numeric Mdm Resp Only
Show IP Address After
RING
Indicates whether to display the remote IP address upon
connection. The default setting is Yes.
Endpoint Configuration
Local Port
Enter the local port number.
Auto increment local
port number
Select to auto-increment the local port number for new
outgoing connections. The range of auto-incremented port
numbers is 50,000 to 59,999 and loops back to the beginning
when the maximum range is reached.
Remote Port
Enter the remote port number.
Remote Host
Enter the IP address of the remote device.
Common Options
Telnet Com Port Cntrl
This field is available for configuration only when
Active
Connect
is set to
None
. Select
Enable
to permit Telnet
communication to the unit. The
Telnet Com Port Cntrl
feature is used in conjunction with the Com Port Redirector
(CPR) utility. (See the CPR online Help for details.)
Terminal Name
This field is available for configuration only when Telnet Mode
is set to
Enable
.
Use the terminal name for the Telnet terminal type. Enter only
one name. When this option is enabled, the unit also reacts to
the EOR (end of record) and binary options, which can be
used for applications such as terminal emulation to IBM hosts.
Connect Response
A single character is transmitted to the serial port when there
is a change in connection state. Default setting is None.
Use Hostlist
If this option is set to
True
, the device server scrolls through
the host list until it connects to a device listed in the host list
table. Once it connects, the unit stops trying to connect to any
others. If this connection fails, the unit continues to scroll
through the table until it is able to connect to another IP in the
host list.
The host list is disabled for Manual Mode and for Modem