6: Configuration via Serial Mode or Telnet Port
WiPort Embedded Wireless Device Server User Guide
46
Figure 5-2. Setup Menu Options
Change Setup:
0 Server
1 Channel 1
2 Channel 2
3 E-mail
4 WLAN
5 Expert
6 Security
7 Defaults
8 Exit without save
9 Save and exit Your choice ?
5. Select an option on the menu by entering the number of the option in the
Your
choice
? field and pressing
Enter
.
View the current configuration by pressing
Enter
from the Change Setup menu.
To enter a value for a parameter, type the value and press
Enter
. To confirm a
current value, press
Enter
(without inputted parameters).
6. When finished, save the new configurations (
9 Save and exit
). The unit reboots.
Serial Port Access
To configure the unit through a serial connection:
1. Connect a console terminal or PC running a terminal emulation program to your
unit's serial port. The default serial port settings are 9600 baud, 8 bits, no parity,
1 stop bit, no flow control.
2. Reset the WiPort unit by cycling the unit's power (turning the power off and back
on). Immediately upon resetting the device, enter three lowercase
x
characters
(
xxx
).
Note:
The easiest way to enter Setup Mode is to hold down the
x
key at
the terminal (or emulation) while resetting the unit. This must be done
within three seconds of resetting the WiPort.
3. Upon connection, the following information displays:
Figure 5-3. MAC Address
MAC address 00204A8943AC
Software version V6.8.0.2 (121024)
AES library version 1.8.2.1
Press Enter for Setup Mode
4. To enter the Setup Mode, press
Enter
within 5 seconds.
Note:
Connection fails if
Enter
is not pressed within 5 seconds.
The configuration settings display, followed by the setup menu options: