6: Configuration via Serial Mode or Telnet Port
WiPort Embedded Wireless Device Server User Guide
55
Hostlist
If this option is set to True, the device server scrolls through the
host list until it connects to the first available device listed in the
host list table. Once it connects, the unit stops further attempts. If
this connection fails, the unit continues to scroll through the table
until it is able to connect to the next available IP address in the
host list.
Hostlist supports a minimum of 1 and a maximum of 12 entries.
Each entry contains the IP address and the port number.
The hostlist is disabled for Manual Mode and for Modem Mode.
The unit will not accept a data connection from a remote device
when the hostlist option is enabled.
Figure 5-5. Hostlist Example
Baudrate (9600) ?
I/F Mode (4C) ?
Flow (00) ?
Port No (10001) ?
ConnectMode (C0) ?25
Hostlist :
No Entry !
Change Hostlist ? (N) Y
01. IP address : (000) 172.(000) 19.(000) 0.(000) 1 Port :
(0) ?23
02. IP address : (000) 172.(000) 19.(000) 0.(000) 2 Port :
(0) ?3001
03. IP address : (000) 172.(000) 19.(000) 0.(000) 3 Port :
(0) ?10001
04. IP address : (000) .(000) .(000) .(000)
Hostlist :
01. IP : 172.019.000.001 Port : 00023
02. IP : 172.019.000.002 Port : 03001
03. IP : 172.019.000.003 Port : 10001
Change Hostlist ? (N) N
Hostlist Retrycounter (3) ?
Hostlist Retrytimeout (250) ?
DisConnMode (00) ?
FlushMode (00) ?
DisConnTime (00:00) ?:
SendChar 1 (00) ?
SendChar 2 (00) ?
To enable the hostlist:
1. Enter a
Connect Mode
of 0x20. The menu shows a list of current entries already
defined in the product.
2. To delete, modify, or add an entry, select
Yes
. If entering an IP address of
0.0.0.0, that entry and all others after it are deleted.
3. After completing the hostlist, repeat the previous step if necessary to edit the
hostlist again.
4. For
Retrycounter
, enter the number of times the Lantronix unit should try to
make a good network connection to a hostlist entry that it has successfully
ARPed. The range is 1-15, with the default set to 3.