background image

Lantronix 

Install Guide, SISPM1040-362-LRT and SISPM1040-384-LRT-C 

33727 Rev. J                                                     

 https://www.lantronix.com/

                                          Page 

48

 of 

51

 

Compliance 

EMI: CE, FCC Part 15, EN61000-4-2, EN61000-4-3, EN-61000-4-4, EN61000- 4-5, EN61000-4-6, EN61000-4-8, 
EC60068-2-32 (Free fall), IEC60068-2-27 (Shock), IEC60068-2-6 (Vibration), NEMA TS-2. 
Safety: IEC 62368-1:2014 (Second Edition); and/or EN 62368-1:2014/A11:2017; and/or BS EN 62368-
1:2014+A11:2017. UL Class 1/Div 2  
Compliant: EN50155, EN50121-4, DNV, IEC61850-3, IEEE1613.  

High Risk Activities Disclaimer 

Components, units, or third-party products used in the product described herein are NOT fault-tolerant and are NOT 
designed, manufactured, or intended for use as on-line control equipment in the following hazardous environments 
requiring fail-safe controls: the operation of Nuclear Facilities, Aircraft Navigation or Aircraft Communication Systems, Air 
Traffic Control, Life Support, or Weapons Systems ("High Risk Activities"). Lantronix and its supplier(s) specifically disclaim 
any expressed or implied warranty of fitness for such High Risk Activities.

 

Cautions and Warnings  

Definitions 

 

Cautions 

indicate that there is the possibility of poor equipment performance or potential damage to the 

equipment. 

Warnings 

indicate that there is the possibility of injury to person.  

Cautions and Warnings appear here and may appear throughout this manual where appropriate. Failure to read 
and understand the information identified by this symbol could result in poor equipment performance, damage 
to the equipment, or injury to persons.  

Caution 

 

While installing or servicing the power module, wear a grounding device and observe all electrostatic discharge 
precautions. Failure to observe this caution could result in damage to, or failure of the power module.  

 

Warnings 

 

Warning

The equipment is to be used only in a RESTRICTED ACCESS LOCATION and installed only by trained 

SERVICE PERSONNEL. 

Warning

: Do not connect the power module to an external power source before installing it into the chassis. 

Failure to observe this warning could result in an electrical shock, even death.  

Warning

: The power module has a provision for grounding. Equipment grounding is vital to ensure safe 

operation. The installer must ensure that the power module is properly grounded during and after installation. 
Failure to observe this warning could result in an electric shock, even death.  

Warning

: A readily accessible, suitable National Electrical Code (NEC) or local electrical code approved 

disconnect device and branch-circuit protector must be part of the building's installed wiring to accommodate 
permanently connected equipment. Failure to observe this warning could result in an electric shock, even death.  

Summary of Contents for SISPM1040-384-LRT-C

Page 1: ...SISPM1040 384 LRT C SISPM1040 362 LRT SISPM1040 384 LRT C SISPM1040 362 LRT Managed Hardened PoE Switches Install Guide Part Number 33727 Revision J September 2022...

Page 2: ...949 453 3990 Fax 949 453 3995 Technical Support Tel 1 800 526 8766 Tel 1 949 453 3990 or https www lantronix com technical support Sales Offices For a current list of our domestic and international s...

Page 3: ...s add PS DC DUAL 5624T Initial Lantronix rebrand Add IEEE 802 3bt Power Input Ripple and Noise Specification Update contact info Safety Warnings and Cautions These products are not intended for use in...

Page 4: ...Unpacking 14 Desktop Mounting 14 DIN Rail Mounting 15 Wall Mounting Optional 16 Connecting Copper Ports 17 Installing SFP Modules 17 Connecting the DI DO Relay Wires 18 Digital Input and Digital Outp...

Page 5: ...Cable Specifications 41 Power Supply Features and Specifications 41 Industrial Power Supply 25105 42 Industrial Power Supply 25104 43 Power Supply Built in DC OK Relay Contact 44 Power Supply Terminal...

Page 6: ...Hazardous locations Railway Marine Transportation and Substation environments Ordering Information SKU Description SISPM1040 362 LRT Managed Hardened PoE Switch provides 4 10 100 1000Base T PoE ports...

Page 7: ...d separately OCA P181610 18x16x10 Polycarbonate Enclosure Sold separately Manual Overview This manual describes how to install configure and troubleshoot the PoE Switches including how to Install the...

Page 8: ...indicate the current status of each port Check these LEDs to determine the port status The following tables detail the functions and descriptions of these LED indicators Table 1 Power LEDs LED Color S...

Page 9: ...point min Volts V1 PHY TTL LED SFP max 3 465V min 3 135V 5 V2 MAC max 2 625V min 2 375V 5 V3 MAC DDR max 1 575V min 1 425V 5 V4 MAC max 1 05V min 0 95V 5 Issue critical stage for High Temperature ala...

Page 10: ...to the connected device Amber On An abnormal state such as overload status has been detected in the switch Off The port has no active network cable connected or it is not connected to a PoE PD device...

Page 11: ...for Single Ring and Ring Failover quick settings as described below See the Web User Guide or the CLI Reference for more information on Ring configuration and setup Table 6 DIP Switch Descriptions RM...

Page 12: ...e Web User Guide or the CLI Reference for more information Note that Spanning Tree must be disabled for Rapid Ring operation EPS and ERPS are standard protocols that can be used between various vendor...

Page 13: ...RESET Button Description Task to perform Press RESET for SYS LED Behavior Port Status LED Behavior Reset the Switch 2 7 seconds Blinking Green ALL LEDs are Off Restore to Defaults 7 12 seconds Blinki...

Page 14: ...g for possible future use One Switch One Terminal Block Euro Block One printed Quick Start Guide One DIN Rail mounting bracket and two screws One DB 9 to RJ 45 Console Cable Power Supply one or two op...

Page 15: ...s back panel Insert screws and tighten with a screwdriver Figure 2 Attaching DIN Rail Kit to the Switch 2 Insert the upper lip of the DIN rail into the DIN rail mounting kit Press the switch towards t...

Page 16: ...more details 1 Attach the wall mounting plates to rear panel of the chassis Insert screws and tighten then with a screwdriver to secure the plates Figure 5 Attaching Wall Mounting Plates to the Switc...

Page 17: ...connect PDs which support power input in 48 56V range to prevent damage to PDs Installing SFP Modules On the SISPM1040 384 LRT C you can install or remove an SFP module from a SFP port without having...

Page 18: ...res into the and terminals respectively 2 To keep the DI DO Relay wires from pulling loose use a small flat blade screwdriver to tighten the wire clamp screws on the front of the terminal block connec...

Page 19: ...h or low as DI normal when DI stays in normal assume it s set as low then DO will not response But the voltage input change to high DI will show high abnormal and at the same time DO will automaticall...

Page 20: ...d Specifications on page 41 Note Both the switch and Power Supply 25105 25104 must have their ground terminals connected to earth ground Caution Tying the output connection of the DC power supply to e...

Page 21: ...er or place a piece of adhesive tape over the circuit breaker handle to prevent accidental power restoration while you are working on the circuit 3 Insert the negative positive DC wires into the V and...

Page 22: ...you will use for the initial configuration Make sure the PC has the Ethernet RJ45 connector to be connected to the switch via standard Ethernet LAN cable 2 Reconfigure the PC s IP address and Subnet M...

Page 23: ...Login page 7 Click Login to log into the switch The startup page displays see the Web User Guide We recommend changing the default credentials before deploying in the network Note The factory default...

Page 24: ...ss the CLI Attach the RJ 45 serial port on the switch front panel to the cable for Telnet CLI configuration Attach the other end of the DB 9 cable to a PC running Telnet or a terminal emulation progra...

Page 25: ...uration on page 22 4 If you have physical access to the switch check the port LEDs for switch information See the LED Descriptions on page 8 and Troubleshooting LED Indications on page 26 5 Examine ca...

Page 26: ...tor plug is firmly inserted and locked into the port at both the switch and the connected device 2 Make sure the connected device is up and running correctly 3 If the symptom still exists try a differ...

Page 27: ...Global RM Green Amber Ring Master LED LED off disabled no Alarm Green lit Ring Master enabled Amber lit Ring Slave enabled Blinking Amber A single Ring has more than two Masters Global RC Green Amber...

Page 28: ...This means only single port PSE s should normally be used when PD s are deployed outdoors In summary the PD PSE environment is one of these three combinations 1 PoE Source is indoor PD is indoor Env A...

Page 29: ...and exact power consumption Calculate PoE Power Budget To calculate how many 802 3at devices the unit supports divide the Total PoE Budget 130 Watts by 30 Watts To calculate the maximum number of 802...

Page 30: ...e switch port is good Noncompliant cabling or powered devices can cause a PoE port fault use only standard compliant cabling 6 Verify that the total cable length from the switch front panel to the con...

Page 31: ...o a momentary overcurrent condition The PD starts to power up but then quickly powers down 15 Most PoE switches have voltage and current regulators that detect an overcurrent threshold and disconnect...

Page 32: ...0 384 LRT C SISPM1040 362 LRT 33729 API User Guide for SISPM1040 384 LRT C and SISPM1040 362 LRT 33824 Release Notes version specific For Lantronix Documentation Firmware App Notes etc go to https www...

Page 33: ...ribe any action s already taken to resolve the problem e g changing mode rebooting etc ________________ ________________________________________________________________________________________________...

Page 34: ...Efficient Ethernet standard for green Ethernet application X X IEEE 802 3af at Power over Ethernet X X IEEE 802 3af at Power over Ethernet X X IPv4 IPv6 L3 static route X X ITU T G 8031 Ethernet Line...

Page 35: ...67F 40 to 75C 40 to 167F 40 to 75C Storage Temperature 40 to 185F 40 to 85C 40 to 185F 40 to 85C Operating Humidity 5 to 95 non condensing 5 to 95 non condensing Altitude 10 000 ft 3000 m 10 000 ft 30...

Page 36: ...shooting Network diagnostic between master switch and devices Supports protection mechanisms such as rate limiting to protect your devices from brute force downloading Supports performance management...

Page 37: ...I in the switch IEEE 802 1X IEEE802 1X RADIUS authentication authorization and accounting MD5 hash guest VLAN single multiple host mode and single multiple sessions Supports IGMP RADIUS based 802 1X D...

Page 38: ...Ports ports can be mirrored to single destination port A single session is supported UPnP The Universal Plug and Play Forum was formed to standardize discovery and control of networked devices See th...

Page 39: ...f devices connected to the switch interfaces Perform on demand backup and restore of device configuration Perform secure remote device firmware upgrades Lantronix hosted public cloud offering LPM Lant...

Page 40: ...0W Number of Ports that support PoE 15 4W PoE 30W Each of ports 1 4 support PoE PoE within available PoE SISPM1040 384 LRT C Available PoE Power 240W Number of Ports That Support PoE 15 4W PoE 30W Eac...

Page 41: ...Watts 25105 Input 85 264 VAC 124 370 VDC Output 48 55 VDC 2 5A 120 Watts PS DC DUAL 5624T Hardened 345 Watt Isolated PS with 56VDC and 24VDC Dual Output Caution Tying the output connection of the DC...

Page 42: ...0VAC Leakage Current 1 0mA 240VAC Protection Overload 110 150 Overvoltage 56 65V Over Temperature 95 C 5 C Environment Oper Temp 25 C 70 C Stor Temp 40 C 85 C Humidity 20 95 non condensing Features 91...

Page 43: ...ection Overload 105 160 Overvoltage 56 65V Environment Operating Temp 25 C 70 C Storage Temp 40 C 85 C Operating Humidity 20 95 non condensing Features 94 High Efficiency 150 Peak Load Protected again...

Page 44: ...n Number Assignments TB1 The power supply s TB1 pinout is provided below Pin Number Assignment 1 FG 2 AC N 3 AC L Power Supply Terminal Block Pin Number Assignments TB2 The power supply s TB2 pinout i...

Page 45: ...Lantronix Install Guide SISPM1040 362 LRT and SISPM1040 384 LRT C 33727 Rev J https www lantronix com Page 45 of 51 Power Supply Dimensions 25104 SDR 240 48 Dimensions in mm 25104 SDR 240 48...

Page 46: ...ated PS with 56VDC and 24VDC Dual Output The Power Supply provides 345W at 56VDC and is targeted for PoE applications The Power Supply is fully compliant with IEEE 802 3af at and bt PoE standards for...

Page 47: ...to comply with the protection requirements of European Emission Standard EN55022 EN61000 3 and the Generic European Immunity Standard EN55024 Declaration of Conformity Manufacture s Name Lantronix In...

Page 48: ...he possibility of injury to person Cautions and Warnings appear here and may appear throughout this manual where appropriate Failure to read and understand the information identified by this symbol co...

Page 49: ...anslated into multiple languages Electrical Safety Warnings Electrical Safety IMPORTANT This equipment must be installed in accordance with safety precautions Elektrische Sicherheit WICHTIG F r die In...

Page 50: ...Canadian National Standards Listed These devices are open type devices that are to be installed in an enclosure only accessible with the use of a tool suitable for the environment This equipment is su...

Page 51: ...rate Headquarters 48 Discovery Suite 250 Irvine CA 92618 USA Toll Free 800 526 8766 Phone 949 453 3990 Fax 949 453 3995 Technical Support Online https www lantronix com technical support Sales Offices...

Reviews: