Connecting the DI/DO Relay Wires
The lower Euro Block (Terminal Block) provides connection of the optional DI/DO Relay wires.
Figure 9: Connecting DI/DO Relay Wires
1.
Insert the negative (ground)/positive DI/DO Relay wires into the
+
and
-
terminals, respectively.
2.
To keep the DI/DO Relay wires from pulling loose, use a small flat-blade screwdriver to tighten the wire-
clamp screws on the front of the terminal block connector.
3.
Insert the terminal block connector prongs into the terminal block receptor.
Notes
:
Digital Output
(relay): 24VDC/1A.
Digital Input
: level 0 (Low) -> 0V to 6V, level 1 (High) -> 10V to 24V.
You can co
nfigure the normal modes of digital input/output (DI/DO) via the Web UI at
the
Home
>
Configuration
>
System
>
Digital I/O
page. See the Web User Guide.