background image

5

Selecting/Preparing Counter Location

1.  Select a level, well ventilated location that is in close       

proximity to a properly grounded electrical outlet, within five 

(5) feet (1.5 m) of a drain, a water supply that meets the 

requirements shown in the Specifications section found on 

page 4, away from direct sunlight or overhead lighting, and 

has sufficient clearance for air circulation. 

2. 

Sufficient clearance must be provided (if an ice maker is 

not installed) to allow filling ice compartment from a five (5) 

gallon bucket (a minimum of 16 inches is recommended). 

ENSURE SUFFICIENT CLEARANCE

 

FOR FILLING WITH ICE 

FS22 DISPENSER, NO ICEMAKER

ENSURE KEYSWITCH 

IS ACCESSIBLE

NOTE:

 Fill ice with 

merchandiser intact.

5.  Select a location for the remote carbonator, syrup pumps, 

CO

2

 tank, syrup containers, and water filter (recommended). 

 

NSF listed units must be sealed to the counter or have 

four (4) inch legs installed.

NOTE

 

Lancer does 

NOT

 recommend the use of shaved or

 

flake ice in the dispenser. The ice level should not 

 

exceed the height of the metal bin wall when filled 

 manually.

NOTE

4.  Unit may be installed directly on countertop or on legs. If 

installed directly on the counter, unit must be sealed to the 

countertop with an FDA approved sealant. If an icemaker is 

to be mounted on top of dispenser, do not install dispenser 

on legs. 

 

Connecting lines can be run through the back of the 

dispenser or extend down through a counter cutout.

 

NOTE

6.  In order to facilitate proper dispenser drainage, ensure that 

the dispenser is level, front to back and side to side. Place a 

level on the top of the rear edge of the dispenser. The bubble 

must  settle  between  the  level  lines.  Repeat  this  procedure                                                         

for the remaining three sides. Level unit if necessary. 

For optimum performance place the unit at a 0° tilt. The             

maximum tilt is 5°.

3.  Inspect the counter location where the unit is to be installed. 

Verify the selected counter is strong enough to safely                     

support  the  weight  of  the  dispenser,  the  ice,  and  the                                                                                                                        

icemaker (if necessary) after counter cut out is made. The 

total weight (with icemaker) for this unit could exceed 800 

pounds (383.6 kg).

 

To assure that beverage service is accessible to all 

customers, Lancer recommends that counter height 

and equipment selection be planned carefully. The 

2010 ADA Standards for Accessible Design states that 

the maximum reach height from the floor should be no 

more than 48” if touch point is less than 10” from the 

front of the counter, or a maximum of 46” if the touch 

point is more than 10” and less than 27” from the front 

of the counter. For more information about the 

 

customer’s legal requirements for the accessibility of 

installed equipment, refer to 2010 ADA Standards for 

Accessible Design - http://www.ada.gov.

NOTE

Summary of Contents for SENSATION 4800

Page 1: ...cease operation of the unit and contact authorized service technician Service cleaning and sanitizing should be accomplished only by trained personnel Applicable safety precautions must be observed I...

Page 2: ...attempting any internal maintenance The resettable breaker switch should not be used as a substitute for unplugging the dispenser from the power source to service the unit Only qualified personnel sh...

Page 3: ...eau connect s directement une alimentation en eau potable doivent tre calibr s install s et maintenus selon les lois f d rales provinciales et locales La conduite d alimentation en eau doit tre un tuy...

Page 4: ...t for concealed damage If evident notify delivering carrier and file a claim against the same NOTE 6 If leg kit has been provided assemble legs by tilting unit The drain spider is located to the right...

Page 5: ...nted on top of dispenser do not install dispenser on legs Connecting lines can be run through the back of the dispenser or extend down through a counter cutout NOTE 6 In order to facilitate proper dis...

Page 6: ...lo para que el ice puede moverse sin obstrucci n Contacto con su proveedor de fabricaci n de hielo para informaci n sobre adecuado bin termostato ATTENTION ATENCI N Failure to use an ice bin thermosta...

Page 7: ...de proc der des raccordements lectriques AVERTISSMENT 12 Route drain hose from designated open type drain to fitting on Drip Tray and connect hose to fitting Drain line must be insulated with a closed...

Page 8: ...ting D Oetiker Pliers D A Tee Fitting B Line to Syrup Pump C Fitting D Line to CO2 Supply A B B C D A Syrup Pump Inlet B Fitting C BIB Connector D Oetiker Pliers A B C D Installing CO2 Supply 1 Connec...

Page 9: ...dispensador debe tener un circuito el ctrico independiente No use cables de extensi n No conecte varios dispositivos el ctricos al mismo tomacorriente F ADVERTENCIA La distributrice doit tre mise la...

Page 10: ...t NOTE A B A Water ON B Syrup Closed 3 Using a Lancer ratio cup verify water flow rate 5 oz in 4 sec Use a screwdriver to adjust if needed 4 Remove nozzle by twisting counter clockwise and pulling dow...

Page 11: ...140 F 60 C Puede da ar la m quina expendedora NO vierta soluci n desinfectante en ning n tablero de circuitos Aseg rese de que toda la soluci n desinfectante sea removida del sistema Utilisez des gan...

Page 12: ...all removable parts Ensure agitator clip is locked 14 Fill Unit with ice and replace Top Cover 15 Reconnect Dispenser to power source Refer to the Automatic Agitation Warning on page 3 NOTE D fense d...

Page 13: ...t Residual sanitizing solution left in the system creates a health hazard Despu s de la esterilizaci n enjuague con el producto final hasta que eliminar el sabor que queda No enjuague con agua fresca...

Page 14: ...ot check to see if the solenoid leads are connected to the PC board or damaged check continuity of solenoid Replace if defective D9 This light is on when the motor is activated When the chute is depre...

Page 15: ...CONDS SWITCH AUTO AGITATE OFF TIME 3 4 OFF OFF NO AUTO AGITATION OFF ON 20 MINUTES ON OFF 40 MINUTES ON ON 60 MINUTES To prevent possible harm to the environment from improper disposal recycle the uni...

Page 16: ...Lancer Corp 800 729 1500 Technical Support Warranty 800 729 1550 custserv lancercorp com lancercorp com Wiring Diagram 115 Volt...

Reviews: