AUTOMATIC AGITATION AND LOW ICE ALARM CONTROL

LED Warnings

LED

DESCRIPTION

D3

This light is on when the ice dispense switch is activated. If the chute is depressed and the light does not turn

on, check to see if the wire harness is connected or if the dispense switch is defective.

D4

This light is used on units with lid interlock switches. On the 4500 series ice-beverage dispenser, this light should 

always be lit. If it is not, check the Lid Interlock Jumper (black wire with 4 pin white connector).

D5

This light is on when +5VDC is present at the circuit board. It should be lit whenever the unit is connected to a 

power source. If the light is off, check to see if the internal circuit breaker on the transformer has tripped. If it has 

tripped, it can be reset by depressing the switch on the top of the transformer.

D6

This light is on when +32VDC is present at the circuit board. It should be lit whenever the unit is connected to a 

power source. If the light is off, check to see if the internal circuit breaker on the transformer has tripped. If it has 

tripped, it can be reset by depressing the switch on the top of the transformer.

D7

This light flashes when there is no ice between the sensors in the ice bin. If the bin is empty and the light is not 

flashing, check all wiring harnesses.

D8

This light is on when the solenoid is activated. When the chute is depressed, this light should turn on. If it does 

not, check to see if the solenoid leads are connected to the PC board or damaged, check continuity of solenoid. 

Replace if defective.

D9

This light is on when the motor is activated. When the chute is depressed, this light should turn on. If it does not, 

check to see if the motor harness is connected to the PC board or damaged, check continuity of motor harness 

and motor. Replace if defective.

 

Light Emitting Diodes (LEDs) are provided on the PC Board to aid in troubleshooting electrical difficulties. Referring to 

 

the wiring diagram included in this manual (also affixed to the electrical box cover), the following information can be 

 

obtained from the LEDs.

NOTE

 

Each Series 4800 ice beverage dispenser is equipped with automatic agitation for the ice bin. Referring to the tables on the 

 

wiring diagram included in this manual (also affixed to the electrical box cover), the automatic agitation timing can be changed as 

 

follows. A set of DIP switches is provided to control the timing and low ice control. Refer to graph below.

DIP #3 & #4 – AUTOMATIC AGITATION FREQUENCY

 

The default ON time is preset to 3 seconds. Automatic agitation should not be used with extruded ice types. Only 

 

use this feature when dispensing cubed ice.

DIP #5 through #8 – DISPENSE TIME/AGITATION SYNC

Switch

Function

Default Setting

Avail Time Settings

#7 and #8

Set the amount of total dispense time before 

agitation occurs

12 seconds

6 seconds

9 seconds

12 seconds

15 seconds

#5 and #6

Set the agitation time (should be less than the 

dispense time). If using an icemaker, the 

agitation time can be decreased

7 seconds

5 seconds

7 seconds

9 seconds

11 seconds

Summary of Contents for SENSATION 4800

Page 1: ...cease operation of the unit and contact authorized service technician Service cleaning and sanitizing should be accomplished only by trained personnel Applicable safety precautions must be observed I...

Page 2: ...attempting any internal maintenance The resettable breaker switch should not be used as a substitute for unplugging the dispenser from the power source to service the unit Only qualified personnel sh...

Page 3: ...eau connect s directement une alimentation en eau potable doivent tre calibr s install s et maintenus selon les lois f d rales provinciales et locales La conduite d alimentation en eau doit tre un tuy...

Page 4: ...t for concealed damage If evident notify delivering carrier and file a claim against the same NOTE 6 If leg kit has been provided assemble legs by tilting unit The drain spider is located to the right...

Page 5: ...nted on top of dispenser do not install dispenser on legs Connecting lines can be run through the back of the dispenser or extend down through a counter cutout NOTE 6 In order to facilitate proper dis...

Page 6: ...lo para que el ice puede moverse sin obstrucci n Contacto con su proveedor de fabricaci n de hielo para informaci n sobre adecuado bin termostato ATTENTION ATENCI N Failure to use an ice bin thermosta...

Page 7: ...de proc der des raccordements lectriques AVERTISSMENT 12 Route drain hose from designated open type drain to fitting on Drip Tray and connect hose to fitting Drain line must be insulated with a closed...

Page 8: ...ting D Oetiker Pliers D A Tee Fitting B Line to Syrup Pump C Fitting D Line to CO2 Supply A B B C D A Syrup Pump Inlet B Fitting C BIB Connector D Oetiker Pliers A B C D Installing CO2 Supply 1 Connec...

Page 9: ...dispensador debe tener un circuito el ctrico independiente No use cables de extensi n No conecte varios dispositivos el ctricos al mismo tomacorriente F ADVERTENCIA La distributrice doit tre mise la...

Page 10: ...t NOTE A B A Water ON B Syrup Closed 3 Using a Lancer ratio cup verify water flow rate 5 oz in 4 sec Use a screwdriver to adjust if needed 4 Remove nozzle by twisting counter clockwise and pulling dow...

Page 11: ...140 F 60 C Puede da ar la m quina expendedora NO vierta soluci n desinfectante en ning n tablero de circuitos Aseg rese de que toda la soluci n desinfectante sea removida del sistema Utilisez des gan...

Page 12: ...all removable parts Ensure agitator clip is locked 14 Fill Unit with ice and replace Top Cover 15 Reconnect Dispenser to power source Refer to the Automatic Agitation Warning on page 3 NOTE D fense d...

Page 13: ...t Residual sanitizing solution left in the system creates a health hazard Despu s de la esterilizaci n enjuague con el producto final hasta que eliminar el sabor que queda No enjuague con agua fresca...

Page 14: ...ot check to see if the solenoid leads are connected to the PC board or damaged check continuity of solenoid Replace if defective D9 This light is on when the motor is activated When the chute is depre...

Page 15: ...CONDS SWITCH AUTO AGITATE OFF TIME 3 4 OFF OFF NO AUTO AGITATION OFF ON 20 MINUTES ON OFF 40 MINUTES ON ON 60 MINUTES To prevent possible harm to the environment from improper disposal recycle the uni...

Page 16: ...Lancer Corp 800 729 1500 Technical Support Warranty 800 729 1550 custserv lancercorp com lancercorp com Wiring Diagram 115 Volt...

Reviews: