13
Ice Chute Cleaning
Removal of Ice Chute for Service
1. Disconnect power to the dispenser.
2. Remove the merchandiser.
3. Disconnect the wire harness for the auger motor.
4. Remove the C-clip from the auger shaft.
5. Support the auger motor. Remove four (4) screws securing
the auger motor mounting plate.
6.
Slide the motor off the auger shaft.
1.
Turn off power to the dispenser.
2. Remove merchandiser.
3. Remove Splash Plate Assembly by lifting it up and out from
the dispenser face.
4. Remove clip from auger motor shaft. Remove four (4)screws
from brackets.
5. Remove the ice chute shell.
6. Remove the ice chute assembly base by removing the four
(4) screws that attach it to the unit.
7. Prepare the Cleaning Solution described on page 13.
8. Soak the ice chute assembly in the cleaning solution.
9. Rinse and dry the ice chute assembly thoroughly.
10. Reinstall the ice chute components.
11. Reinstall merchandiser.
12. Reconnect power to the dispenser.
It is recommended to perform this procedure monthly,
or more often if desired. Use the cleaning solution
described above. An alternate solution of one part
water to one part vinegar may be used to remove
water spots and calcium deposits.
NOTE
DO NOT
discard the shaft key.
NOTE
Ensure motor harness is disconnected and retain the
auger shaft key.
NOTE
Following sanitization, rinse with end-use product
until there is no aftertaste. Do not use a fresh water
rinse. This is a NSF requirement. Residual sanitizing
solution left in the system creates a health hazard.
Después de la esterilización, enjuague con el
producto final hasta que eliminar el sabor que queda.
No enjuague con agua fresca. Ésta es una exigencia de
NSF. Si queda solución de esterilización en el sistema,
genera un peligro para la salud.
Défense de rincer l’outil à l’eau fraiche immédiatement
après un traitement septique. En cas de après-goût, ne
purger avec le produit final une exigence NSF.
!
CAUTION
!
PRECAUCIÓN
!
PRUDENCE
Cleaning and Sanitizing Nozzles
1. Disconnect power, so as to not activate valve while cleaning.
2. Remove nozzle by twisting counter clockwise and pulling
down.
3.
Remove diffuser by pulling down.
4.
Rinse nozzle and diffuser with warm water.
5.
Wash nozzle and diffuser with cleaning solution then
immerse in sanitizing solution and let sit for fifteen (15)
minutes.
6.
Set nozzle and diffuser aside and let air dry.
DO NOT
rinse
with water after sanitizing.
7.
Reconnect diffuser and nozzle.
8. Connect power.
9.
Taste the drink to verify that there is no off-taste. If off-taste
is found, flush syrup system again.
A
B
C
A. Nozzle
B. Diffuser
C. Soda Lever
7. Remove the two (2) auger motor mounting plate support
brackets by removing the four (4) screws securing brackets
to the mounting plate.
8. Unhook the ice chute spring from the ice chute.
9. Remove the ice chute assembly from the mounting plate by
removing the screws securing it into place. Be sure to retain
the o-ring from between the ice chute assembly and the
feed-through.
10. Remove the outer ice chute from the base by pushing the
hinge tabs inward to release the outer ice chute.