1. Bonus Flavors
a. Decide if the bonus flavors will be set to add an injected flavor to the
brands or dispense carbonated water/plain water.
b. Choose the
V
alve number (1-2) by scrolling
UP
and
DOWN
arrows.
c. Use the
LEFT
and
RIGHT
arrows to shift to the
T
op,
M
iddle, or
B
ottom
"bonus" flavors categories.
d. Press the
UP
and
DOWN
arrows under
T
op,
M
iddle, or
B
ottom to select
it as an injected flavor, carbonated
S
oda water, or plain
W
ater.
e. Press
ENTER
to finalize settings. Panel lights should confirm finalized
configurations.
2. Brands
a. Decide how the brands will be setup.
b. Choose the
V
alve number (1-2) by scrolling
UP
and
DOWN
arrows.
c. Use the
LEFT
and
RIGHT
arrows to shift to the
L
eft or
R
ight categories.
The Left or Right categories are set with the assumption that you
are looking at them from the front.
d. Press
UP
and
DOWN
arrows under
L
eft (1-2) or
R
ight (1-2) to select the
brand per side as a single or double. For example, for bezel PN 05-2120,
V:1 L:1 R:2
3. Soda/Water
a. Decide which switch locations will be carbonated and/or non-carbonated
drinks.
b. Choose the
V
alve number (2-3) by scrolling the
UP
and
DOWN
arrows.
c. Use the
LEFT
and
RIGHT
arrows to shift to the number categories (
1-4
).
The number categories correspond to the brand location (per valve)
that is being configured.
d. Press the
UP
and
DOWN
arrows under the number to select if that brand
will be carbonated
S
oda or non-carbonated plain
W
ater. If a single brand
per side, only number
1
and/or
3
need to be set.
4. Automatic Agitation
a. Each Series 14400 ice beverage dispenser is equipped with automatic
agitation for the ice bin. The unit is shipped with timing set at two seconds
(2000 milliseconds) ON every sixty minutes for cubed ice. The unit is
shipped with timing set at four seconds (4000 milliseconds) ON every
150 minutes for pellet ice.
3.3
PURGING THE CARBONATION SYSTEM
Purge the carbonator tank whenever carbonation issues occur.
A. Turn off CO
2
supply.
B. Turn off power to the unit. Unplug the carbonator harness from the power
supply.
C. Open the relief valve until water is coming out. Close the relief valve, checking
for any remaining air in the tank.
D. Allow the carbonator tank to fill with plain water by way of the water booster.
24
P.N. 28-0580/02