29
P.N. 28-0580/02
TROUBLE
CAUSE
REMEDY
CONTINUED ON NEXT PAGE
4.14
Insufficient syrup flow.
A. Insufficient CO2 pressure to
BIB pumps.
B. Shutoff on mounting block not
fully open.
C. Foreign debris in syrup flow
control.
D. Defective BIB pump.
A. Adjust CO2 pressure to 80 PSI
(min 70 PSI) for BIB pumps.
B. Open shutoff fully.
C. Remove syrup flow control
from valve and clean out any
foreign material to ensure smooth
spool movement.
D. Replace pump.
4.15
Erratic ratio.
A. Incoming water and/or syrup
supply not at minimum flowing
pressure.
B. Foreign debris in water and/or
syrup flow control.
C. CO2 regulator malfunction.
A. Check pressure and adjust.
B. Remove flow control from
suspected valve and clean out
any foreign material to ensure
smooth spool movement.
C. Repair or replace CO2
regulator as required.
4.16
Water only dispensed, no
syrup. Or syrup only dispensed,
no water.
A. Syrup BIB empty.
B. Water or syrup shutoff on
mounting block not fully open.
C. Improper or inadequate water
or syrup supply.
D. CO2 pressure to syrup pump
too low.
E. Stalled or inoperative BIB
pump.
F. Kinked line.
G. CO2 regulator malfunction.
A. Replace syrup BIB as required.
B. Open shutoff fully.
C. Remove valve from mounting
block, open shutoff slightly and
check water and syrup supply. If
no supply, check dispenser for
other problems. Ensure BIB
connection is engaged.
D. Check the CO2 pressure to the
pump to ensure it is between 70-
80 PSI.
E. Check CO2 pressure and/or
replace pump.
F. Remove kink or replace line.
G. Repair or replace CO2
regulator as required.