18
Set the time to 12:01 PM, then exit the
time programming mode . Then,
simultaneously press and hold buttons
and for 5 seconds.
1. Display unit (DF)
- Litre
[ L t r ]
2. Valve type (VT)
- Concurrent, 1 backwash (standard)
[ d F 1 b ]
3. Regeneration type (CT)
- Delayed volumetric
[ F d ]
4. Valve type (NT1)
- Program that must not change
- Cyclic capacity m
3
°Resin filters:
Lt 8=44 - Lt 15=82
Lt 22=121 - Lt 30=165
6. Inlet water hardness (H)
Volumetric version visible only
- Metric format, French degrees (°F)
7. Reserve type (RS)
7.1 Reserve with fixed volume (RC)
E.g. 1200 litres
7.2 Safety factor in % (SF)
E.g. 15% reserve capacity
8. Regeneration day override (DO)
E.g. Regeneration every 7 days
9. Regeneration time (RT)
E.g. Regeneration 2.00
1. Press the button
to
switch from one display to
another.
2. Adjust the parametric
values using buttons and
.
3. Depending on the
programming,
some
screens may not appear
and others cannot be
changed.
Valve 5600