Free prescaler for volumetric sensor
Information
The free prescaler can be set from 0.1 to 99.9.
Information
The free prescaler is set by default to 14 (applies to turbine with only one magnet).
Information
This option is displayed only if
FP
(prescaler flag) is set to 0.
Set the prescaler free.
A
Use
and
to set the free prescaler.
B
Press
to confirm and go to the next parameter.
Number of regenerations before salt alarm
Information
The number of regenerations before the salt alarm can be set from 0 - CO - 99.
Information
CO is a salt alarm generated by the resistivity check of the water drained during the
brine draw phase.
Set the number of regenerations before the salt alarm
lights up on the controller’s display.
A
Use
and
to set the number of regenerations.
B
Press
to confirm and go to the next parameter.
Days enabled for regeneration
Information
This option is displayed only if
SH
(regeneration mode) is set to 0.
Set the days enabled for regeneration. The display shows "dx y" where "x" is the day of the
week (1 - 7) and "y" shows whether the selected day is enabled for regeneration ("1") or not
("0").
For each enabled day, the top of the display shows the relevant flashing icon.
A
Use
to edit the setting of the selected day "x".
B
Use
to enable or disable the selected day "y".
C
Press
to confirm and go to the next parameter.