Alarm messages
Inhibit signal
There is an inhibit signal input. The following screen
alternates with the service screen on the display. Any
incoming regeneration is blocked.
Salt alarm
No salt in the brine tank. Fill the brine tank with salt if a
sensor is present. Fill the brine tank with salt and press any
of the controller buttons. During the salt alarm, regenerations
are not carried out.
Technical support request
Active at regular intervals (in weeks) that may be set by the
after-sales service. The alarm is deactivated by pressing any
of the controller buttons.
The support request icon flashes when regeneration of the
conductivity probe is finished.
FR01
End of cycle alarm. The module cannot find the end of
cycle. During the end of cycle alarm, regenerations are not
carried out.
Alarms relating to conductivity during regeneration
These alarms are displayed in the statistics or by simultaneously pressing
and
for
5 seconds.
AL01
Salt quantity too low during phase 2.
AL02
Sensor reading lost during regeneration
AL03
Conductivity sensor alarm absent or disconnected.
AL04
Conductivity not properly restored after regeneration. The technical support icon
flashes.