11
• In any case, any faults caused by improper installation and/or piping connections may void the
warranty on Lamborghini Caloreclima products.
• Similarly, using lubricant* on the valve thread is not allowed and will void the warranty for the
valve and tank. Indeed, using lubricant there will cause the valve to be over-torqued, which may
lead to valve thread or tank thread damage even if the connection to the piping has been done
following the above procedure.
*Note: The use of petroleum-based grease and mineral-based lubricants is strictly forbidden, not only on the valve
thread, as contact between plastic (especially Noryl) and this type of grease may lead to structural damage and result in
breakages.
Bypass
A bypass valve system must be installed in all water conditioning systems. Bypass valves isolate
the softener from the water system and allow unconditioned water to be used. Service or routine
maintenance procedures may also require the system to be bypassed.
Caution
Do not solder pipes with lead-based solder.
Caution
Do not use tools to tighten plastic fittings. Over time, stress may break the
connections.
Caution
Do not use petroleum grease on gaskets when connecting bypass plumbing. Use
only 100% silicone grease products when installing plastic valves. Non-silicone
grease may cause plastic components to fail over time.
Information
Always provide a bypass valve for the installation, if the unit is not equipped with one.
Information
Depending on the system configuration, several types of bypass are possible.
NO
NO