Zip Hydroboil Plus - Installation & Operating Instructions - 89956UK - January 2012 v1.04                 Page 1 of 16

Installation and Operating Instructions

Zip Hydroboil Plus

®

Large boiling water

Affix Model Number Label Here

 89956UK

Summary of Contents for 89956UK

Page 1: ...droboil Plus Installation Operating Instructions 89956UK January 2012 v1 04 Page 1 of 16 Installation and Operating Instructions Zip Hydroboil Plus Large boiling water Affix Model Number Label Here 89...

Page 2: ...Page 2 of 16 Zip Hydroboil Plus Installation Operating Instructions 89956UK January 2012 v1 04 This page intentionally left blank...

Page 3: ...Read these warnings first 4 Installation Requirements 4 5 Installation Procedures 5 7 Step 1 Positioning 5 Step 2 Fastening 5 See page 6 Wall Mounting Template Dimensions Step 3 Connecting 6 a Plumbi...

Page 4: ...g the heater from the power supply Do not use strong corrosive or abrasive cleaners to clean the case of the heater Frost protection If this heater is located where ambient air temperature could fall...

Page 5: ...tap to be not less than 200 mm above the draining board height should be increased only if essential for filling larger vessels Provide clearance for service access of not less than 150 mm top 65 mm l...

Page 6: ...dversely affect the operation of the heater The heater must be installed with an isolating valve which allows it to be isolated from the mains supply for servicing Water pressure requirements Minimum...

Page 7: ...outlet Turn power ON After a short period boiling water will be available and will be maintained close to boiling point thereafter Initial heating periods are shown in the table on the left Warning t...

Page 8: ...panel until it latches in the closed position and the unlocked indicator is illuminated Warning The unit is now capable of dispensing boiling water without the safety feature Dispensing Boiling water...

Page 9: ...n have 2 ON OFF times per day If the user selects either of the energy saver modes see below ON OFF mode cannot be used The user is not able to access this part of the configuration The real time cloc...

Page 10: ...the ambient light in the room where the Hydroboil Plus is installed drops below 100lux the unit goes into energy saver mode and will allow the temperature of the stored water to drop to and be mainta...

Page 11: ...2 To increment the Minutes press CSS3 To step to the next configuration parameter press CSS1 SET DAY OF THE WEEK To return to Normal Mode press CSS4 To step to the next day of the week press either CS...

Page 12: ...Light sensor is configured as on pressing CSS1 will return the user to Normal Operation Note 3 If both Sleep Mode and Low Light sensor is configured as off the user will be able to use ON OFF mode SUN...

Page 13: ...rrectly Please contact your local city council for collection centre details Problem Solving Sympton Possible Cause Solution Fails to dispense water Water isolating valve turned off Blocked filter blo...

Page 14: ...9 90102UK Cistern Float S Nut Kit 10 90495UK Banjo Screw Kit 11 90174UK Contactor Kit 12 90743UK Fascia Lens 13 90994UK Fascia Assy Electronic White 13 90995UK Fascia Assy Electronic Grey 14 90620UK...

Page 15: ...Page 15 of 16 Zip Hydroboil Plus Installation Operating Instructions 89956UK January 2012 v1 04 Spare Parts 7 RQQHFWRU 6 RQQHFWRU 21 IRU Contactor Only for 40L...

Page 16: ...tration cartridge installed with the appliance as cartridge life may vary according to water quality and the rate of water consumption Zip does not exclude restrict or modify any liability that cannot...