Follow now the next steps to complete the operator set up.
1.
Turn on main power supply on both operators.
2.
If the digital programmer N-DSEL has been used before, the display will show "No Communication”
because the new serial numbers of the operator's board L-NEP are not stored in the programmer N-DSEL.
Press and hold for about 5 seconds the SET push button to enter the general programming menu, and from there select the submenu
"Serial communication setting" (as indicated in par. 16).
·
If the digital programmer N-DSEL is new and is powered for the first time, you will be required to choose your preferred language as
specified in paragraph 14.1, then you will automatically enter the "Serial communication setting".
3. SERIAL COMMUNICATION SETTING
The programmer N-DSEL recognizes the presence of the two operators in the system (Fig. A) and acquires
automatically the serial
number of the logic boards L-NEP (fig. B).
At the end of the acquisition of the logic boards serial numbers, the display will show the symbol closed padlock on the icons with letters M
and S (fig. C) and the programmer N-DSEL will be able to manage
both master and slave operators.
fig. A
fig. B
fig. C
Press EXIT (SET) push button to exit from “Serial communication setting” and come back to the
.
general programming menu
4. INITIAL SET-UP
From the general programming menu , enter in the “INITIAL SET UP” section (as indicated in par. 16)
Enter the 10 digits of the technique password to access the configuration set-up.
(for more information on using technique password, see the par. “Password management” 19 and 19.1).
In this section the push-button F1 / F3 set the OFF / ON state of the function.
With the push-button you go to the next function, with the F2 you return to the previous function.
5. SETTING OF THE DOUBLE LEAF FUNCTIONS.
·
Set function S01 ON = double leaf door.
·
The function F2 is related just at the models SLT-B, SLT, LET-B, LET.
Select if the closing cycle must use only the force
of the spring (OFF), or if also activate the motor (ON)
for ensure greater strength of reclosing.
·
The S03 function must be set ON just in case an electro-lock is set on the door.
Only on the Master operator the electro-lock output will be activated.
·
The function S04 is displayed only if function S03=ON.
Select the electro-lock type installed:
OFF
: electric strike;
ON
: maglock.
52