A = Adjusting area of opening speed
controlled by P01 parameter
B = Adjusting area of slowing down
distance controlled by P12 parameter
C = Adjusting area of approach speed
A+C = Opening time
A = Adjusting area of closing speed
controlled by P02 parameter
B = Adjusting area of slowing down
distance controlled by P13 parameter
C = Adjusting area of approach speed
A+C = Closing time
A = Adjusting area of Push&Go controlled
by P08 parameter, before automatic
opening
B = Adjusting area of Push&Close
controlled by P22 parameter, before
automatic closing.
A = Area from where, if safety sensor in
opening detect an obstacle, the door opens
at low speed instead of stop moving
depending of potentiometer P03 value.
A = Intervention area of Wind Stop with
opened door. The opposing force is
controlled by P24 parameter.
B = Intervention area of Wind Stop with
closed door. The opposing force is
controlled by P07 parameter.
Rate (in %) of intervention area, controlled
by P14 parameter, in which the motor
operated during closing stroke. Motor
power can be adjusted by P15 parameter.
FIG.1
A
B
C
0%
100%
FIG.2
C
0%
100%
B
A
FIG.3
A
B
FIG.4
A
FIG.5
A
B
FIG.6
1%
10%
50%
75%
100%
The following drawings show the regulation areas of some parameters described in the spreadsheet in order to better understand its
purpose. In the spreadsheet the column “Ref. Drawing” is indicating the drawing number to be checked for any parameter for which a
relative drawing has been added.
38