22.2) MAGNETIC LOCK
Functions settings to activate magnetic lock:
Ÿ
F04 = ON
to activate electric lock output.
Ÿ
F05 = ON
to enable permanent driving, that keep magnetic lock powered with
closed door.
In the working program “Manual” the magnetic lock isn't powered with door closed,
so to move door manually.
Activating “Push & Go” function (P08 parameter), the magnetic lock isn't powered
with door closed in the automatics working program to allow manually opening. It
work only in the “Night lock” program.
23)
SAFETY SENSOR DEVICES
This section describes how to connect and configure properly some of the safety sensors in compliance with the standard EN12987
available on the market, to ensure a level of safety corresponding to PL = c, Category 2 as required by the standard EN16005.
23.1) SENSOR OA-EDGE T
WIRING CONNECTION SENSOR OA-EDGE T
WIRING CONNECTION
NEPTIS SMP OPERATOR
Wiring between the sensor and the terminal block of the PWN-T board on Neptis SMP operator
1. WHITE (+) Supply power
TERMINAL 17 (+)
2. BROWN (-) Supply power
TERMINAL 16 (-)
3. GREEN COM (Closing side)
TERMINAL 3 COM
4. YELLOW N.C. (Closing side)
TERMINAL 2 Safety sensor in closing
5. GREY N.O. (Closing side) do not connect
6. PINK COM (Opening side)
TERMINAL 7 COM
7. BLUE N.C. (Opening side)
TERMINAL 5 Safety sensor in opening
8. RED N.O. (Opening side) do not connect
9. BLACK (+) Test input
TERMINAL 25 TEST (+)
10. VIOLET (-) Test input
TERMINAL 26 GND (-)
DIP SWITCH SETTING ON OA-EDGE T PARAMETERS ON DIGITAL PROGRAMMER N-DSEL
A7 = ON
Low level test input.
F20 (S07) = ON
For safety sensor in closing
A8 = OFF
Input test delay 10msec..
F21 (S08) = ON
For safety sensor in opening
For other option and settings available on
F22 (S09) = OFF
Test level LOW
the safety sensor, see the instructions supplied
with the sensor OA-EDGE-T.
SETTING ON THE L-NEP BOARD
Jumper J13 =
position
P
47