This document is the exclusive property of FTFM La Toulousaine and must on no account be copied. It may be modified at any time in accordance with product changes.
_N°7386
Installation_Totem operator (Sliding gate)
09/21
p.16
Lock the operator
1
-
First learning cycle :
Measuring distance
(it will be done at reduced speed).
a) Press the START button, the gate moves to the opening limit
stop (opening limit
-
switch LED lights up).
Please note :
If the gate closes, re
-
set the
switch 7
(
see chapter :
DIPS switch settings).
b) Wait for validation click
(◄
and
►
turn on and off).
c) Press the START button, the gate moves to the closing limit
stop (closing limit
-
switch LED lights up).
d) Wait for validation click
(◄
and
►
turn on and off).
2
-
Second learning cycle :
Force measurement
(slowing down at the end).
-
Redo the same procedure :
Follow the steps of the first
learning cycle (a, b, c and d)
.
Information :
After the 2 learning cycles have been completed,
the "Light" LED must go out ; the learning cycle is completed.
Please note :
If the "Light" LED stays on, repeat the entire
learning cycle again.
Please note :
The learning cycles are in hold
-
to
-
run mode.
Please note² :
Check that the LED "Light" is flashing,
if not flashing, reset the board.
(
see chapter :
Resetting the board).
Move gate to intermediate position
Self
-
learning
1
2
3