This document is the exclusive property of FTFM La Toulousaine and must on no account be copied. It may be modified at any time in accordance with product changes.
_N°7386
Installation_Totem operator (Sliding gate)
09/21
p.13
Connection plan
2
-
Phase L1 (black)
3
-
Neutral N (blue)
5
-
Earth (green/yellow)
Power supply 230V
DIPS switch factory settings
-
Position switch 7 according to the opening direction.
-
Check switch 8 whether it
’
s ON.
Switch
ON
OFF
Description
1
X
Hold to run mode deactivated
If ON : Hold to run mode activated
2
X
Reaction to input safety contact strip / switch
-
off
Partial reversal
If ON : Full reversal
3
X
Locked weight potentiometer
(Never switch to OFF)
4
X
Reaction of the cells during closure
Full reversal
If OFF : Partial reversal
5
X
Sleep off
If OFF : Sleep enabled
6
X
The triggering of the cells starts a time delay (gate open)
If ON : The gate closes 5 seconds after passing through the cells
7
ON : Left opening gate (exterior view)
OFF : Right opening gate (exterior view)
8
X
ON : Pre
-
alert timeout enabled
If OFF : Early warning time is disabled
Board (wireless accessory management)
Cells, 4 wires
Cells, 2 wires
P
ote
n
tia
l
-
fr
ee
r
ela
y co
nt
act/
m
a
x.2
4V
C
C/CA
STOP button
Gate button CLOSED
Pulse button
O
P
E
N
P
ULS
E
CLO
S
E
D
S
T
OP
Power supply, 4 wires
24V
warning light
Open button
partial/time delay
input
Emergency stop
push button
P
ar
tia
l o
p
en
in
g
Please note :
20V output, terminals 8/10