Message
Remedy
Coffee boiler
filled?
First installat.
Enter to confirm
•
This espresso machine is equipped with several
feedback mechanisms that alert the operator when
an unusual condition occurs. Additionally the
espresso machine will warn the operator when
certain parameters fall below or above the
programmed point. These errors and warnings will
appear as a message in the display
•
The following section will describe errors and
warnings that may appear in the display
Description
Press the ENTER button on group 1 keypad to confirm. Then will initialize the CPU and
boot the electronics.
This message is displayed after the
boilers have been drained. The CPU is
verifying that the coffee boiler is full.
Description
This is the first installation of the
espresso machine and the CPU is
asking for verification of this event.
Fill the coffee boiler with water (see operating manual for detailed instructions). Ensure that
all air is bled from the coffee boiler using the air bleed screw atop each group casting. The
CPU will display this message to ensure that the coffee boiler is full before supplying power
to the coffee boiler heating element.
Filling-up
in progress
Corrupted
Data
Most likely the machine power was disconnected with out first turning off the machine
through the keypad and display. Turn off machine using main switch to cycly power on and
off. This should clear the error
No action is required when this message is displayed. This message is only displayed to
notify the operator of the active process.
This message is displayed when the
CPU does not understand an
instruction.
This message is displayed when the
steam boiler autofill cycle is activated
and water is entering the steam boiler.
Steam Boiler
Empty
Filling-up
Alarm
When this message is displayed the CPU also shuts down and turns off power to the
machine (see the parameter “Level Timeout”). Press the ON/OFF button to reset this error.
This message is displayed when the
CPU does not receive any signal from
the Safety Probe in the steam boiler.
This message is displayed when the
CPU does not detect a full signal from
the steam boiler within the set time
interval.
When this message is displayed the CPU turns off power to the steam boiler heating
element. The only way to reset this error is to repair the Safety Probe to restore the signal
to the CPU.
Flowmeter
Alarm
Steam Boiler
Temperature
When this message is displayed call an authorized service technician to repair this fault.
The also CPU turns power off to the steam boiler.
When the flowmeter alarm is displayed, the light on the corresponding button that initiated the brew cycle
will begin to flash. This problem is a result of water not flowing through the flow meter. This can be caused
by the coffee packed too tightly, a blockage in the tubes, a malfunctioning water pump, a faulty valve, or a
damaged flowmeter. Call a service technician to fix this problem.
This message is displayed when the
steam boiler temperature exceeds the
maximum allowed temperature.
This message is displayed when the
CPU does not receive the appropriate
signal from the flowmeter.
Coffee Boiler 1
Temperature
Coffee Boiler 1
Heating
See the parameter “Heating Timeout” for more information. The number on the display
corresponds to the number of the faulty coffee boiler.
This message is displayed when the
coffee boiler temperature exceeds the
maximum allowed temperature.
This message is displayed when the
coffee boiler does not reach the
minimum temperature with the
programmed time interval.
If this happens call an authorized service technician to repair this fault. When this message
is displayed the CPU turns power off to the coffee boiler displayed. The number in the
display corresponds to the faulty coffee boiler.
Wrong
Password
Autosteam 1
Temperature
If this happens call an authorized service technician to repair this fault. The number in this
message indicates the faulty Autosteam assembly.
This error message will be displayed anytime an incorrect password is entered. The display
will reset automatically after 3 seconds. Then an addional attempt may be made.
This message is displayed when the
autosteam temperature exceeds the
maximum allowed temperature.
This message is displayed when
password entered does not match the
programmed password.