English
Description
Firenze - Italia
Display
Operating Procedure
9
www.lamarzocco.com
Version 1.3
GB/5 - FB/80
Factory Level Parameters
Nominal Coffee Boiler Temperature
Coffee Boilers
Temperatures
•
This parameter is set at the factory at a preset
nominal temperature.
•
The set temperature of this parameter differs from
the actual temperature of the water exiting the group
to the coffee.
•
The temperature of the boiler is measured at the
most critical point in the boiler when temperature
fluctuation is the greatest.
•
The temperature of the water exiting the group head
is held constant by means of the mass of the group
casting. Even though the temperature of the boiler
may vary a few degrees, the temperature of the
water exiting the group is constant.
•
To set the temperature of any espresso machine it is
important to measure the temperature of the water
exiting the group.
Password
?????
Press and hold the
button on the group 1 keypad until the following is displayed
(approximately 10 seconds):
1
LaMarzocco 09:30
Enter the 5 digit factory password using buttons 1-5 on the group 1 keypad. Once accepted the
following appears:
2
Groups Number
3
3
Press the
button on the group 1 keypad until the following appears (two times):
MODE
Coffee Boiler 1
202.5
°
F 202.6
°
F
4
Press the
button to select the coffee boiler you wish to change temperature.
Coffee Boilers
Temperatures
ENTER
Press the
or the
button to change the temperature on the displayed boiler. The
measured temperature appears on the left and the set temperature appears on the right side of the
display. Once the desired temperature is selected press the button
to confirm the selection.
5
+
ENTER
Repeat procedure 5 for all subsequent boilers (if installed).
6
When finished, continue to the next parameter or press
to exit programming mode.
7
ON
OFF
Software Programming Manual - ENG - V 1.3.pmd
30/10/2006, 14.39
9