Steam Boiler Temperature Correction
Technician Level Parameters
•
This parameter allows the technician to adjust the
pressure of the steam boiler by raising or lowering
the temperature of the steam boiler.
•
This parameter is only active when the parameter
“Steam heat.Type” is set to “Temp Probe”.
Password
?????
LaMarzocco 09:30
Language
English
Steam Temp Cor.
Press and hold the
button on the group 1 keypad until the following is displayed
(approximately 10 seconds):
Enter the 5 digit technician password using buttons 1-5 on the group 1 keypad. Once accepted the
following appears:
1
2
Press the
button on the group 1 keypad until the following appears (about eight times):
3
MODE
When finished, continue to the next parameter or press
to exit programming mode.
5
ON
OFF
4
Steam Temp Cor.
Press the
or the
button to adjust the temperature higher or lower. Each block is equal to
0.5°F. Once the desired setting is made press the button to
confirm the setting.
+
MODE
The saturation temperature of water will vary will ambient atmospheric pressure.
Tables in this manual are created for atmospheric pressure at
light
adjustment in temperature will be required for elevations other than sea level.
sea level. S
THE STEAM BOILER CONTAINS WATER AT ELEVATED TEMPERATURES. WATER TEMPERATURE
OVER 125 F CAN CAUSE SEVERE BURNS INSTANTLY OR DEATH FROM SCALDING.
゚