11
4-1-2
Key Operation in Function Selecting Mode
• Press the FUNCTION key for 2 seconds in the measuring mode to activate the function selecting mode. At
this time, function ‘F-01’ is indicated on the indicator.
• By pressing the
→
key or SHIFT +
←
keys in the function selecting mode, various functions are selected
from ‘F-01’ to ‘F-14.’
Select the desired function and press the SET key. Then, the selected function is determined to activate the
function setting mode.
●
There are the following 14 selective functions
F-01: Original value
F-08: Additional Value
F-02: Actual Load Calibration
F-09: Automatic ZERO Compensation
F-03: Sensitivity Registering Calibration
F-10: Hysteresis
F-04: Hold Mode
F-11: BCD Output Logic
F-05: Self Check
F-12: Initialize
F-06: D/A Output Scale
F-13: BV Select
F-07: Smoothing
F-14: TEDS ON/OFF
●
For details of functions, see “4-2-1 Various Functions in Function Selecting Mode.”
• Press the CANC key in the function selecting mode to return to the measuring mode.
4-1-3
Key Operation in Function Setting Mode
• Select the desired function in the function selecting mode and press the SET key to activate the selected
function setting mode.
• To set the required numerical value, change the current numerical value with the
→
, SHIFT +
←
,
↑
, and
SHIFT +
↓
keys and press the SET key. Then, the set value is determined and stored in the memory at the
same time.
• When no numerical value is set, "…...."is indicated. Press the SET key in this state to activate the selected
function.
• Press the CANC key in the setting mode to return to the measuring mode.
●
Numerical Value Setting Procedures
a) When setting the numerical value, setting available digit flickers.
b)
Pressing
the
→
key moves the flickering digit to the right. The flickering digit next to the right end moves
to the left end digit.
Pressing the SHIFT +
←
keys moves the digit the other way round.
c) Pressing
the
↑
key changes the numerical value of the flickering digit as shown in the following.
Flickering digit in left end
→
0
→
1
→
–1
→
–
→
0
→
Other flickering digits
→
0
→
1
→
2
→
3
→
4
→
5
→
6
→
7
→
8
→
9
→
0
→
Pressing the SHIFT +
↓
keys moves the flickering digit the other way round.
d) Set decimal point in calibration functions ‘F-02 and F-03.’
A decimal point moves to the right by pressing the
→
key and moves to the left by pressing the SHIFT +
←
keys.
Pressing the CANC key on the way returns to the previously set function selecting mode.