2BC/D
2-4-1
Timing c
har
t No.
1
F
rom the main s
witch turned on to mac
hine stabilization
2 s
Primary stabilization fixing
temperature 165
°
C/329
°
F
Secondary stabilization fixing
temperature 185
°
C/365
°
F
Aging end
Copying enabled
MSW
DB REM
PCL1 REM
PCL2 REM
PRY
CL REM
MC REM
CFM REM
MSW: On
3 s
1 s
2 s
20 s
20 s
100 ms
300 ms
600 ms
CN13-5
FH-M REM
CN2-5
FH-S REM
CN2-6
MCCM FWD REM
CN4-5
MCCM REV REM
CN4-6
IFM
CN15-A3
CN15-B3
PCM REM
CN12-9
CN4-11
CN4-13
CN4-15
CN19-A3
250 ms
CN12-12
150 ms