(8) Detaching and refitting the heat roller separation claw
Follow the procedure below to replace the heat roller separation claw.
Procedure
1. Open the front cover, tilt the paper conveying
unit release lever down, and pull out the
paper conveying unit.
2. Open the eject cover.
3. Remove the screw holding the thrust pin and
then the pin.
4. Remove the two screws holding the holder
and then the holder. Remove the heat roller
separation claw unit.
5. Remove the spring from heat roller
separation claw.
6. Loosen the screw holding the retainer and
pull out the separation claw shaft.
7. Replace the heat roller separation claw and
all the removed parts.
Heat roller
separation claw unit
Thrust pin
Holder
Separation claw shaft
Heat roller
separation claws
Retainer