Routing and Installing System Cables
Manual Part Number:
006-1219-00 Rev. 0
4–3
Digital Eyewitness
®
HD
In-Car Video System
Figure 4-2.
Power Cable Routed Through Factory Pass-Thru
Managing Excess Cable
In many installations, the technician will end up with excess cable that needs to be properly
managed to avoid creating operation issues with the Eyewitness
®
HD or other vehicle systems.
The technician should
NEVER
coil excess cable. Instead, they should wrap the cable into a
dog bone shape and secure it with cable ties. This will avoid creating unwanted magnetic
fields, which may contribute to RFI.
Figure 4-3.
Managing Cables – Creating a Dog Bone