6. - Putting into service
MERGE MAXX 950
43
KN233BGB_C
Merger
Pin
Wire color
Function
(1) - 82
Brown
+ 12 Volt
(2) - 15/30
Brown
+ 12 Volt
(3) - 31
Blue
Ground
Some tractors are factory equipped with a 3-
pin socket, to prevent any malfunction, check
the polarity of this socket before connecting
the control box.
- Check presence of voltage on pin (1).
6.4
Coupling and uncoupling
6.4.1 Description of coupling elements
• A pto shaft drives the machine's hydraulic pump
for driving the pick-ups and the conveyor belts.
•
An electric 7-pin plug for the signalling
equipment.
• A 3-pin plug for the on-board computer power
supply.
• 4 hydraulic hoses connected to the hydraulic
valve bank that controls the various functions.
• 1 hydraulic hose to supply the braking system
circuit (depending upon specification).
• 2 pneumatic hoses to supply the brake actuation
system (depending upon specification).
• Cord linked to a fixed point of the tractor which
activates the emergency brake in case of linkage
disconnection.
15/30
31
82
1
2
3